Indoor Air Quality Field Report, 90 Trinity Place, May 2002

Machine-extracted title · confidence 95%

ATC Associates indoor air quality field report for 90 Trinity Place documenting environmental conditions in May 2002.

NYC-WTC_000180206–000180219
Page image
Scanned page image, NYC-WTC_000180219
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document SUBJECT TO PROTECTIVE ORDER NO. SEPI. 2008 CONFIDENTIAL, CITY_21MC100_003464239 NYC-WTC_000180219 ATC ASSOCIATES, INC. Page 14 of 14 INDOOR AIR QUALITY FIELD REPORT Time: |:45Pm LOCATION: 90 Trinity Place /HS for Leadership and public services DATE: 5 802 PROJECT NO: 15-19125-0290 Location Occupants Temperature (*F) Relative Carbon Carbon Respirable TVOCS Humidity Dioxide Monoxide Particulate (6) (pm) (ppm) (ppm) s (ug/m") Roan # 305 Room+ 309 tенща YREmEd Hallway ourside it 306 Room t 206 STAIROUELL'AI TO Gym BASEMENT GYM Out Doors MAIN ENTRANCE Out Doors NORTA Of MAIN ENTRAArE Out Doors SOTAOFMAIN ENTRANCE Guideline levels ASHRAE/AIHA 9 74.2 14-2 74.0 76.5 74.5 75.9 17.8 738 23.2 740 68 - 75°F/winter 73-79 °Fsummer 41.6 n9 0-0 419 139 40.6 628 5 42:0 697 0.0 0-0 407 421 599 4 0•0 918 448 1076 / 0-0 0•0 32,8 416 ) 331 413 33-2 - 402 30-60% Outdoor level 9 ppm 8 54 48 12 65 ug/ml 0.0 0.d 1 ppm + 700 ppm Comments: The assessed location(s) () Does () Does not meet established indoor air quality guidelines. sigemare BA. Date:_ 5/8/02

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000180219Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000180169

ATC Associates indoor air quality field report for 90 Trinity Place detailing temperature, humidity, and pollutant levels in March 2002.

Similar indexed content

NYC-WTC_000180049

Field report containing indoor air quality data for 100 Trinity Place collected in May 2002.

Similar indexed content

NYC-WTC_000180033

Field report form documenting indoor air quality measurements taken at a school in May 2002.

Similar indexed content

Compare copies and versions →