WTC environmental investigation report, Sep 2002

Machine-extracted title · confidence 95%

Comprehensive report on airborne and dust exposures in Lower Manhattan following the September 11 attacks, published by the Department of Health.

NYC-WTC_000178388–000178443
Page image
Scanned page image, NYC-WTC_000178404
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Final Technical Report of the Public Health Investigation Page 17 of 56 emanated from the collapse of the WTC towers and that might cause health problems. However, this investigation could not conclude if contaminants or materials found actually came from the disaster. The contaminants that were selected for testing could be present in some areas from other sources. Some typical examples of this include cooking on a stove top, which can increase indoor airborne particulate matter; vehicle exhaust, which can increase outdoor airborne particulate matter; and recent home renovation activities, which can result in an increase in levels of gypsum, fiberglass, and other materials in air and surface dust.

METHODS

Details on the methods used in the residential sampling investigations are included in the residential sampling plan that is on the New York City Department of Health and Mental Hygiene's Internet page (http://WWW.nvc.Qov/html/doh/pdf/alerts/indoorl.Ddf). Printed copies of the plan can be requested from the New York City Department of Health and Mental Hygiene.

A. Sampling Approach

A series of three concentric circles was drawn around the WTC location. The circles were then divided by direction or zone from the WTC (north, south, and west). Attempts were made to obtain access to the same number of residential buildings per zone for sampling. Four residential buildings above 59th Street were selected for testing to determine what levels of fibers and minerals might be routinely found in the city.

Once a building was selected, air and settled surface dust sampling occurred in up to four different locations: an area outdoors near a main entryway to the building; an area inside of the main entry (or other common area); and two residential units. Informed consent for sampling was obtained and questions were asked about details that could aid in interpreting the sampling results (such as whether the windows were open on the morning of September 11, 2001).

Both air and settled surface dust samples were collected in high traffic or routinely used areas of the space. For example, settled surface dust was collected from areas where individuals frequently walked, not from behind furniture or underneath kitchen appliances. Air sample inlets were at approximately 4 feet in height above the ground/floor surface to provide results more reflective of what might be inhaled.

Attempts were made during air sampling to obtain data that would reflect what might be in the air during periods of high activity. If the selected area was not occupied at the time of sampling, and if there was no central heating or air conditioning system that could result in contaminant migration into another occupied area, aggressive air sampling was conducted. If the area was occupied, the heating or air conditioning system fan was turned on during the period of sampling. This would not represent a period of high activity, but would present data that might be found during typical

http://www.atsdr.cdc.gOv/asbestos/lowermaiihattaii/ResSamp_Sep2002_Text.html 07/18/2003 NYC-WTC_000178404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000178404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →