Settled dust samples were collected from indoor floors by using a specialized vacuum
cleaner. The outdoor samples were collected by scraping visibly settled material into a
container. XRD was used to analyze the crystalline mineral content of each sample.
Results are reported as percent (%) of the specific mineral per weight of the dust sample.
Quartz, calcite, portlandite, gypsum, and mica were found in your building at levels
similar to or lower than those found in the comparison areas. These materials are
common components of building and road construction materials.
Please refer to the previous part of this report (executive summary) for the limitations of
this data, the possible symptoms of exposure, and recommendations on how to reduce
your potential for exposure.
Explanation of Tables 2a and 2b: Fibers found in Air and Settled Dust in Your
Building and the Comparison Areas
Air Sample Collection and Analyses:
Air samples were collected for up to an eight-hour period using vacuum pumps to draw
air past a filter that was suspended at the height of a person’s breathing level. All air
samples were analyzed for total fibers using Phase Contrast Microscopy or PCM. If
levels of total fibers were higher than the PCM levels found in the comparison areas
(0.003 fibers per cubic centimeter of air, or free), the sample was re-analyzed using both
Transmission Electron Microscopy (TEM) and Scanning Electron Microscopy (SEM).
TEM analysis can distinguish asbestos from other fibers; SEM can distinguish fibrous
glass from other fibers.
For an explanation of the asbestos results, please refer to the letter you received from us
earlier this year that contained an enclosure titled: “Summary of Asbestos Sampling
Results.” As PCM results for 2 locations were above levels found in comparison homes,
SEM analysis (for fibrous glass) was conducted for the “residence 1” and “common area”
samples. Results show the fibrous glass was found at levels below those seen in the
comparison homes.
Settled Dust Sample Collection and Analyses:
Settled dust samples were collected indoors and outdoors in the same manner described
previously. At the laboratory, samples were analyzed for asbestos and fibrous glass
fibers using Polarized Light Microscopy (PLM). PLM can distinguish asbestos from
non-asbestos fibers by the appearance and color given off by each different type of fiber.
For an explanation of the asbestos results, please refer to the letter you received from us
earlier this year that contained an enclosure titled: “Summary of Asbestos Sampling
Results.” Indoor settled dust levels of fibrous glass were found at 5% in one location;
none was detected in the comparison homes. No visibly settled dust was available to
collect in your building or in comparison building outdoor locations.
CONFIDENTIAL, CITY_2IMCl00_003434274
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000176157