8 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Analytical laboratory reports attachment for PCDDs and PCDFs, 2008
Machine-extracted title · confidence 85%Confidential attachment containing analytical laboratory reports regarding polychlorinated dibenzo-p-dioxins and furans under a protective order.
NYC-WTC_000175725–000175740
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
’ i 3 IW "z Pace Analytical SarvicBS, Inc. 1700 Elm Street. .Suite 200 ^ace Analytical '; Minneapolis, MN 55414 Phone: 612.807.1700 emw.pacelabs.com RETORT OF: CHEMICAL ANALYSES Fax: 612.607.6444
1 PROJECT: PCDD/PCDF ANALYSES DATE: January 9, 2002
PAGE: 5 REPORT NO: 01-1052682 i @ PCDD/PCDF Quantification and Calculations (Cont.) Each pair of ion mass peaks in the selected-ion-current chromatograms was evaluated manually to Q determine if it met the criteria for a PCDD or PCDF isomer. Areas of all peaks exhibiting correct ion Ji ratios, having, Tetention times within the correct windows, and having areas corresponding to concentrations''" in the range covered by the initial calibration were then summed for calculations of total congener concentrations. The toxic equivalence of each sample was calculated using the factorsjlsted in Table 5.
limit of detection (LOD) based on producing a signal that is 2.5 times the noise level, was calculated for each undetected 2,3,7,8-substituted isomer of any tetra through octa chlorinated congener class. The noise heights used to calculate the detection limits were measured at the M retention time of the specific isomer. The formula used for calculating the LOD is: iai Hn X Qis X 2.5 LOD = La His X W X Rf where: • 3 LOD = Single isomer limit of detection Hn = Sum of noise heights at native isomer retention time Qis = Quantity of labeled internal standard His = Sum of peak heights for labeled internal standard Sample amount
I = Response factor
, , The recovery of the 2,3,7,8-TCDD-®’Cl4 enrichment efficiency standard and each ’^Cij-labeled Ji internal standard, relative to either 1,2,3,4-TCDD-’^C,2 or 1,2,3,7,8,9-HxCDD-^^Ci2, was calculated using the following equation:
I %R = Ais X Qrs X 100%
Rfr X Ars x Qis ra where:
, %R = Percent recovery of labeled internal standard ! Ais = Sum of integrated areas of labeled internal standard Qrs = Quantity of recovery standard - Ars = Sum of integrated areas of recovery standard f Rfr = Response factor of the specific labeled internal standard relative to the recovery standard Qis = Quantity of the labeled internal standard congener added to the sample
j REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services. Inc.
CONFIDENTIAL, CITY_21MC100_003432698 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175731
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
9 shared non-person entities · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗10 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175186
Cover page for a laboratory report containing 17 pages of analytical results conforming to NELAC standards for the Department of Education.
5 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000175115
Laboratory report presenting results for polychlorinated dibenzo-p-dioxins and dibenzofurans in four samples analyzed using USEPA Method 8290.
5 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000178033
Confidential laboratory analysis report appendix from [name] Services regarding World Trade Center samples.
3 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗3 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000060283
Laboratory report documenting GCMS analysis of sample AE06408 conducted on May 3, 2002.
Similar document embedding; no shared entity or topic indexed. · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130438
Draft special investigative audit report on environmental data from the World Trade Center site prepared by IT Corporation.
3 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content