Wipe sample results for dioxins, P.S. 124, Nov 2002

Machine-extracted title · confidence 98%

Report from ATC Associates detailing polychlorinated dibenzo-p-dioxin and dibenzofuran wipe sample analysis conducted at a New York City school.

NYC-WTC_000175533–000175534
Page image
Scanned page image, NYC-WTC_000175534
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr Bernard P Orlan November 25, 2002 Wipe Samples for Dioxins Page 2 P S 124 Manhattan ATCProiectNo 15-19125-0350

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxm (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (m nanograms) for the analytical results for each sample A copy of the laboratory analysis report is attached The results are shown m the following table

DIOXIN WIPE SAMPLE RESULTS 2,3, 7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^) September 12, 2002 LOCATION /SAMPLE ID DIOXIN CONCENTRATION

Lobby-Mam Entrance / DX-1 0 00

2nd Floor Hallway by Room 222 / 0.000035 DX-2 3rd Floor Hallway by Room 307 / 0 00 DX-3 Blank / DX-4 0.00

The New York State Department of Health (NYSDOH) established guidelines for dioxm for the re-occupancy of the Binghamton State Office Building following a PCB fire The NYSDOH guideline for dioxm on surfaces is 25 nanograms per square meter (25 ng/m^)

The concentrations on indoor surfaces ranged from 0 00 to 0 000035 nanograms per square meter (ng/m^) The levels found m all of these samples are below the NYSDOH guideline of 25 ng/m2

It IS not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected m these samples was deposited Dioxm samples were not collected from these locations prior to these samples therefore a background sample is not available for comparison purposes

It IS our pleasure to provide these indoor environmental services to the NYC Department of Education If you have any questions about this report, please call (212) 353-8280, extension 212

Sincerely, ATC Associates, Inc.

James R Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC1OO_OO3431433 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175534

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175534Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →