Mr Bernard P Orlan November 25, 2002 Wipe Samples for Dioxins Page 2 P S 124 Manhattan ATC Protect No 15-19125-0350

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers The results for each isomer were then converted to 2, 3, 7, 8 tetra'chloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanograms) for the analytical results for each sample A copy of the laboratory analysis report is attached The results are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2,3, 7, 8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m-) September 12,2002

Lobby-Main Entrance / DX-1 0 00

2nd Floor Hallway by Room 222 / 0 000035 DX-2 Srd Floor Hallway by Room 307 / 0 00 ___________ DX-3___________ Blank / DX-4 0.00

The New York State Department of Health (NYSDOH) established guidelines for dioxm for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxm on surfaces is 25 nanograms per square meter (25 ng/m^)

The concentrations on indoor surfaces ranged from 0 00 to 0.000035 nanograms per square meter (ng/m^) The levels found in all of these samples are below the NYSDOH guideline of 25 ng/m2.

It IS not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples was deposited. Dioxin samples were not collected from these locations prior to these samples therefore a background sample is not available for comparison purposes.

It is our pleasure to provide these indoor environmental services to the NYC Department of Education If you have any questions about this report, please call (212) 353-8280, extension 212

Sincerely, ATC Associates, Inc.

James R Cohn, CIH, CSP Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_003041818

NYC-WTC_000196572

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000196572Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →