Mr Bernard P Orlan November 25 2002 Wipe Samples for Dioxins Page 2 P S 1 (Manhattan) ATCProiectNo 15 19125 0340

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers The results for each isomer were then converted to 2 3 7 8 tetrachloro dibenzo p dioxin (2 3 7 8 TCDD) equivalents by multiplying by an established equivalency factor This provides a single value (in nanograms) for the analytical results for each sample A copy of the laboratory analysis report is attached The results are shown m the following table

DIOXIN WIPE SAMPLE RESULTS 2 3 7 8 TCDD EQUIVALENTS Nanograms per square meter (ng/m^) August 27 2002 LOCATION /SAMPLE ID DIOXIN CONCENTRATION

Mam Lobby /DXl 0 000083

Hallway by Room 215 /DX2 0 00018

Hallway by Room 403 / DX3 0 000045 1

The New York State Department of Health (NYSDOH) established guidelines for dioxin for the 5 re occupancy of the Binghamton State Office Building following a PCB fire The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^)

The concentrations on indoor surfaces ranged from 0 000045 to 0 00018 nanograms per square meter (ng/m^) The levels found m all of these samples are below the NYSDOH guideline of 25 ng/m2

It IS not possible to determine when the 2 3 7 8 TCDD equivalents detected m these samples was deposited Dioxin samples were not collected from these locations prior to these samples therefore a background sample is not available for companson purposes

It IS our pleasure to provide these indoor environmental services to the NYC Department of Education If you have any questions about this report please call (212) 353 8280 extension 212

Sincerely ATC Associates, Inc

James R Cohn CIH CSP Regional Manager Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_21MC100_003431180 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000175475

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000175475Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →