NYC 9/11 Public Portal Document
CorvinAS. IflC-
k.
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6444
Client - ATC
Client's Sample ID ATC-0222-STY-DX1
Lab Sample ID 103343323
Filename U20311A_12
Injected By CVS
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
I ICAL Date
CCal Filename(s)
03/11/2002
U20311A_07 & U20311A_22
Received
Extracted
02/25/2002
03/05/2002
Method Blank ID BLANK-1499 Analyzed 03/11/2002 20:37
1 Native
Isomers
Cone
ng/m2
EMPC
ng/m2
LRL
ng/m2
Internal
Standards
ng's
Added
Percent
Recovery
2,3.7,8-TCDF ND 0.0026 A 2,3,7,8-TCDF-13C 2.00 85
1 Total TCDF ND 0.0020 2,3,7,8-TCDD-13C
1,2,3,7,8-PeCDF-13C
2,3,4,7,8-PeCDF-13C
2.00
2.00
2.00
71
86 N2
83 *N2
2,3,7,8-TCDD ND 0.0035 A
Total TCDD ND 0.0020 1,2,3,7,8-PeCDD-13C 2.00 58 N2
1,2,3,4,7,8-HxCDF-13C 2.00 99
1,2,3.7,8-PeCDF ND 0.0100 1,2,3.6,7,8-HxCDF-13C 2.00 83
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 91
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 100
1,2,3,4,7,8-HxCDD-13C 2.00 102
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 71
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 80
1,2,3,4,7,8,9-HpCDF-13C 2.00 82
1,2,3,4,7,8-HxCDF ND 0,0100 1,2,3,4.6,7,8-HpCDD-13C 2.00 81
1,2,3,6.7,8-HxCDF ND 0.0100 OCDD-13C 4.00 52 N2
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4,7,8-HxCDD ND 0.0100 2,37,8-TCDD-37CI4 0.20 80
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.014 0.0100 J
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1.2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00031 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4.6,7,8-HpCDD 0.021 0.0100 J
Total HpCDD 0.033 0.0100 J
OCDF ND 0.0200
OCDD 0.098 0.0200 BJ
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2.3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
a = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1054413
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429591
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175055
OCR can misread numbers and units. Confirm readings against the page image before using them.