NYC 9/11 Public Portal Document
FEB-2B-02 13!2O FROM-PACE ANALYTICAL 612-607-6444 T-765 P.05/05 F-351
1700 Elm Street - Suite 200
/^^^ceAnalvticar Minneapolis, MN G5414
Tel: 612-607-1700
Fax- 61?- 607-644.4
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0206-STY-DX4
Lab Sample ID 103311817
Filename U20226B_11
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/0B/2002
ICAL Date 02/26/2002 Received 02/08/2002
CCal Fil©nams(s) U20226A^10 & U2022eB_15 Extracted 02/19/2002
Method Blank ID BLANK-1476 Analyzed 02/27/2002 02:09
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND 0.0029 A 2,3,7,8-TCDF-13C 2.00 72
Total TCDF ND 0.0020 2,3,7.8-TCDD-13C 2.00 68
1.2.3.7.8-PeCDF-13C 2.00 78
2,3,7,8-TCDD ND 0.0033 A 2,3,4.7.8-PeCDF-13C 2.00 81
Total TCDD ND 0.0020 1,2.3,7,8-PeCDD-13C 2.00 78
1,2.3.4,7,8-HxCDF-13C 2.00 93
1,2,3,7,8-PeCDF ND 0.0100 1,2.3,6,7,8-HXCDF-13C 2.00 78
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6.7.8-HxCDF-13C 2.00 75
Total PeCDF ND 0.0100 1,2,3,7,8,9-HXCDF-13C 2.00 85
1,2,3.4.7.8-HxCDD-13C 2.00 64
1.2,3.7,a-PeCDD ND 0.0100 1,2,3,6,7,8-HXCDD-13C 2.00 73
Total PeCDD ND 0.0100 1.2,3,4,6,7,8-HpCDF-13C 2.00 60
1,2,3.4,7,8.9-HpCDF-13C 2.00 57
1.2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,G,7,a-HpCDD-13C 2.00 53
1,2.3,6.7,8-HxCDF ND 0.0100 OCDD-13C 4.00 49
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3.7,S.9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 l,2.3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4.7,8-HxCDD ND 0.0100 2.3.7.8-TCDD-37C14 0.20 80
1,2.3,6,7,B-HxCDD ND 0.0100
1 ,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2.3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,B-TCDD
1.2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2.3,4,6,7.8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD ND 0.0200
lRl = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substliuted isomers) I - Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on sfemal-tD-noise measurement S = Saturatea signal
1 J = Concentration detected is below the calibration range
B = Less than 10 times higher than method blank level
ND = Not Detected
NA = Not Applicable
P = Recovery outside ol target range NC = Not Calculated
Nn = Value Obtained from additional analysis • = See Discussion
Report No..,..02-1053891
REPORT OF LABORATORY ANALYSIS
This report shall not ba reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_21MC100_003429578
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000175050
OCR can misread numbers and units. Confirm readings against the page image before using them.