NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM Asbestos air analysis results, Oct 2001

Machine-extracted title · confidence 95%

Laboratory report documenting transmission electron microscopy analysis of an air sample for asbestos received October 1, 2001.

NYC-WTC_000174938
Page image
Scanned page image, NYC-WTC_000174938
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (air) Count Sheet sample area analyzed B" Client Name: HP ENVIRONMENTAL, INC. Job#: 101101001 Volume /liters): 570.0 Lab Sample #: 04 Filter Type / Filter Area: MCE 385 mm2 Client Sample #: ET-TRL-0929-A3 Grid Opening Size: 0.01003 Received: 10/01/2001 02:00:17 Area Examined: 0.10030 mm2 Date Analyzed: 10/01/2001 Magnification: 20,000 Scope #: 4 Accelerating Voltage: 100 KeV Analysis Performed by: Whitney m Grid Length Width Location Opening Fiber /tM mm Fiber Type Morphology EDS Orient. SAED Photo B8-C3/3 1 NSD U BS-E3/3 9 NSD U B8-F3/3 3 1 2.5 .06 Chrysotile Matrix Mg, Si, Fe / 40056 40056 B8-G3/3 4 1 1.0 .06 Chrysotile Matrix Mg. Si, Fe / 12^1 B8-G3/3 4 2 1.30 .06 Chrysotile Fiber Mg, Si, Fe I B8-H3/3 5 NSD U B9-C3/3 6 NSD U B9-E3/3 7 1 4.6 .06 Chrysotile Cluster Mg, Si, Fe * B9-E3/3 7 2 1.75 .06 Chrysotile Fiber Mg, Si, Fe \ B9-E3/3 7 J 1.0 .06 Chrysotile Fiber Mg, Si, Fe / 1^ ^9-E3/3 7 4 12.75 .06 Chrysotile Matrix Mg, Si, Fe / 9-E3/3 7 5 1.5 .06 Chrysotile Fiber Mg, Si, Fe / B9-F3/3 8 1 1.25 .06 Chrysotile Matrix Mg, Si, Fe I 1^ B9-G3/3 9 1 2.25 '<06 Chrysotile Matrix Mg, Si, Fe I B9-H3/3 10 1 2.30 .’06 Chrysotile Matrix Mg, Si, Fe \

NSD; No Asbestos Structures Detected Comments Structure Density Concentration Total Grid Openings; 10 (str/mm2) (str/cc air) Grid Evaluation Chrysotile Asbestos Structures: 11 109.7 0.0741 Grid Openings Covered > 50% Amphibole Asbestos Structures: 0 <10 <0.0067 3 Intact Grid Opening > 50% Asbestos Structures >=5 microns: 1 10.0 0.0067 3 Undissolved Filter < 10% Total Non-Asbestos Structures; 3 Folded Replica < 50% Total Asbestos Structures: 11 109.7 0.0741 3 Filter Loading < 10% Analytical Sensitivity: 10 0.0067 3 Particulate Even 06.002243

CONFIDENTIAL, CITY_21MC100_013442370 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000174938

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000174938Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM asbestos air analysis results, Oct 2001

NYC-WTC_000174937

Laboratory report from HP Environmental Inc. detailing transmission electron microscopy analysis of an air sample received October 1, 2001.

Similar indexed content

Compare copies and versions →