NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet sample area
analyzed
Client Name: HP ENVIRONMENTAL, INC.
Job#: 101101001 Volume (liters): 650.0
Lab Sample #: 02 Filter Type / Filter Area: MCE 385 mm2
Client Sample #: ET-TRL-0929-A1 Grid Opening Size: 0.01003
Received: 10/01/2001 02:00:17 Area Examined: 0.10030 mm2
Date Analyzed: 10/01/2001 Magnification: 20,ffiiw
Scope #: 4 Accelerating Voltage: 100 KeV
Analysis Performed by: •7^ iU'H-
WhitneYHi
Grid Length Width
Location Opening Fiber /tM Fiber Type Morphology EDS Orient. SAED Photo
mm
A9-B3/3 1 1 1.25 .06 Chrysotile Fiber Mg. Si, Fe
A9-C3/3 2 NSD U
A9-E3/3 3 NSD U
A9-F3/3 4 NSD U
A9-G3/3 5 NSD U
A10-B5/4 6 NSD u
A10-C5/4 7 1 2.76 .06 ’ Chrysotile Matrix Mg, Si. Fe / 40055 40055
A10-C5/4 7 2 5.5 .75 Chrysotile Bundle Mg, Si, Fe
A10-E5/4 8 NSD u
A10-F5/4 9 NSD u
'.10-G5/4 10 NSD u
K
NSD: No Asbestos Structures Detected
Comments
Structure Density Concentration
Total Grid Openings: 10 (str/rnm2) (str/cc air) Grid Evaluation
Chrysotile Asbestos Structures; 3 29.9 0.0177 KI Grid Openings Covered > 50%
Amphibole Asbestos Structures: 0 <10 <0.0059
KI Intact Grid Opening > 50%
Asbestos Structures >=5 microns: 1 10.0 0.0059 K Undissolved Filter < 10%
Total Non-Asbestos Structures; K Folded Replica < 50%
Total Asbestos Structures: 3 29.9 0.0177 KI Filter Loading < 10%
Analytical Sensitivity; 10 0.0059 K Particulate Even
. 06.002246
CONFIDENTIAL, CITY_21MC100_013442368
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000174937
OCR can misread numbers and units. Confirm readings against the page image before using them.