ATC ASSOCIATES INC. TEM ANALYSIS
LAB GROUP #: 5573 - 09/28/01
Lab .Sample No. ■59626 Filter Type MCE 25 mm Operator.
Client Spl. No. 15 Filter Arsa 385 mm"2 .
Instrument I.D. EM 10 CRX Grid I.D. Disk No.
Screen Magnification 16,400X (GO5 Area 0.01124 mm"2 Comments
Acc. Voltage 8 0 kV No. GO to be Analyzed ( 4.721 Struct. Corspd. to 70 s/mm'^2.)
GO. structure Structure Type Length I.D. of Structure EDS
>0.5 um
(Nonasb.
No Coord. No. F B C M >. Sum Chrys Amphibole Nonasb. Ambig./ND Elements)
< 5 um
2 //
U //
XL f/
1/
rq
lj
n
ij
r*.
tJ
U
A. Photo No. (from 1 in 5 aabeatos- llore all unrepealed apectraF
Identify ail atructurea using EDS Check diffracUon for aabeatos
containing samples) Grid acceptance:! structures up to.70a/&g (iat 4)
<S0X undisaoived filter, overlapped or folded
Struct. = > O.Sum Ic > 5:1 Aspect Ratio <10X particulate coverage >6QX coverage Totals
N- Not Observed (EOS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares
Foflitlve diffraction pattern properties confarminf
<5X holes or opaque areas________ _______________ F B C M > Sum
to laboratory identification criteria obaerved. •Unuaed portion
For ebryaotile: 0.73nm spaeine for (020) rsflBctioni,
0.53nm ipaeing for the layer Une repeat, streaking
of filter Chrysotile
-Avoided portion
at (no) and (130) refleeUona. of fitter
Por amphiboles; 0.a3nm layer line repeat, and approx. Portion of filter (Zmrn side)
3.5 ratio of nan-twinned layer Une spot apacing to subject to
examination
Amphibole
layer Une repeat distance (0.52nm).
EDS spectrum conforming to laboratory
Identification criteria observed. AMPHIBOLES Ambiguous
Fa Single Fiber (1-3 intersecLiona = 1-3 fibers) Amosite
3= Bundle f>3 fibers <1 fiber diametar apart) 2&mm filter Crocidolite Non—asbestos
□
C= Cluster (>3 intersections) f Stopping Rules: L
Ms Matrix [* Anthophyllite
NSDs No Structures Detected j >50 i/G.O. or in iat 4 G.O. Tremolite
Pl Actinolite
Non-Identified
U\DATA\PRIVATE\M1KKC\CADD'5'KM3 9/22/20
NYC-WTC_000174874