Fiber optic specifications for 7 World Trade Center, Nov 1998

Machine-extracted title · confidence 95%

Technical specification document for sensing and data fiber features at the 7 World Trade Center facility.

NYC-WTC_000171944–000171953

Folder label: “Security Systems for Conduits®Sensing and Data Fiber Features and Specifications

Page image
Scanned page image, NYC-WTC_000171950
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document Nov-10-98 NYC-WTC_000171950 03:12P VIKONICS MAYOR'S OFFICE OF EMERGENCY MANAGEMENT 201 641 7728 P.08s CONDUIT SECURITY SYSTEM SPECHACA TION To avoid nuisance alarms, the low-frequency cutoff is set to around 200 Hz. The high-frequency cutoff is typically set to 450 Hz so that the processor only sees signals related to the uespuss. 2.3.2 Fiber Defender 205 Specifications MAXIMUM ZONE SIZE Perimeters up to 6,500 feet SENSITIVITY Uniform over entire length INPUT VOLTAGE REQUIREMENT 10-24 Vde POWER DRAW 2.1 watts at 12 Vde at 25°C OPERATING TEMPERATURE RANGE -30 to 55°C (Expanded temperature range is available.) OUTPUTS ALARM Jamp N.C.N.O, relay contact COMMUNICATION RS-232C INPUT TAMPER 1 amp. N.O, relay contact ALARM OUTPUT DURATION Programmabte SIZE 6"x 10” x I” FIBER-OPTIC SENSING CABLE FS! Part #SC3 CABLE LIFE EXPECTANCY 20 years CONNECTORS ST type, crimp-on VIKONICS, INC HO2C-$ REV U November 9, 1978

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000171950Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Security system specification excerpt, May 1998 · Box 7DCAS

NYC-WTC_000173219

Technical specification document detailing end-of-line resistor wiring requirements for the Mayor's Office of Emergency Management security system.

1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.929

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

Fire Service Summary Report, n.d. · Box FDNY

NYC-WTC_000169205

Document summarizing fire service activities or inspections performed at the specified location.

Similar document embedding; no shared entity or topic indexed. · similarity 0.893

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →