NYC-WTC_000173475
Letter providing comments on submitted architectural plans for the Mayor's Office of Emergency Management.
Same agency, volume and box · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗Discussion on securing NYPA rates for a building project through direct metering or sub-metering arrangements with the landlord.
NYC-WTC_000168243–000168244Folder label: “Office of Emergency Management (OEM) -Forwarded -Reply -Reply”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
EXHIBIT B
23rd Floor “Shell” Condition
a. Air-Conditioning: 2-45 ton Trane units. The MER has an invertor controlling fan speed. Condenser water is supplied by 5-125 H P. pumps; 3,040 G.P.M. SUMMER; Not more than 76 degrees F dry bulb/INSIDE, when OUTSIDE temperatures reach a high, up to 95 degrees F dry bulb, 74 wet bulb with 5 watts for light and power per rentable square foot and 1 person per 100 rentable square feet. WINTER: Not less than 72 degrees F dry bulb/INSIDE when OUTSIDE temperatures reach a low, up to -10 degrees F dry bulb.
b. Sprinkler system; The sprinkler system is located in the B closet and is provided for all floors. the system is fed from the 6” standpipe riser. Distribution is the responsibility of the tenant. The standpipe system is supplied by 3 risers located in stairway A & B and at column #79 on the North East side of the building. Hoses and racks are provided in these areas. The sprinkler and standpipe systems are supplied by 2 house tanks, 27,000 gallons each with a fire reserve of 7,500 gallons each. Siamese connections.
c. Electrical Power: The building is provided with 4 feeders from the Con Edison sub station. Electrical power is distributed to the floor by 3 bus ducts. 2 of the electrical closets (there are 4) on the floor contain transformers for stepping down the power from 460 volts to 277 and 208/120 volts. Each electrical closet has a distribution panel rated for 70 amps.
d. Windows: The floor has approximately 150 Solar Bronze windows. Window coverings are the responsibility of the tenant.
e. Life Safety systems: The building endeavors to comply with all applicable codes as they apply to its life safety systems.
f. Spray on Fireproofing: Structural steel members are fireproofed in accordance with applicable code. g. Public Corridor Demising Partition; Not required if The City occupies the entire 23rd floor as proposed.
h. Slab Leveling: Not required, 7 World Trade Center is a new building.
7
NYC-WTC_000168244
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000173475
Letter providing comments on submitted architectural plans for the Mayor's Office of Emergency Management.
Same agency, volume and box · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173529
Letter from law firm to City regarding administrative matter related to 7 World Trade Center.
1 shared non-person entities · Same agency, volume and box · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000170996
Proposal document prepared for the Mayor's Office of Emergency Management regarding lease and broker agreements.
1 shared non-person entities · Same agency, volume and box · similarity 0.922
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168246
Excerpt from a report dated August 11, 1997, describing the exterior and condition of World Trade Center 7 for the Mayor's Office of Emergency Management.
3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000170923
Memorandum dated August 11, 1997, submitting a report and photographs of the proposed space for the Mayor's Office of Emergency Management.
3 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000170950
Summary document outlining terms for the Mayor's Office of Emergency Management lease at 7 World Trade Center.
1 shared non-person entities · Same agency, volume and box · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173360
Department of Citywide Administrative Services requests specific clarifications and confirmations for itemized costs in a bid package for 7 World Trade Center.
1 shared non-person entities · 1 shared topics · Same agency, volume and box · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗2 shared non-person entities · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000135975
Document containing illegible text or corrupted data within the Department of Environmental Protection's Athena D Terms records.
Similar document embedding; no shared entity or topic indexed. · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142397
Memorandum outlining procedures for building owners regarding the clean-up of asbestos-containing material after the attacks.
1 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000143501
A scanned page containing fragmented text and symbols from the Department of Environmental Protection archives.
1 shared non-person entities · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140959
Form authorizing the City of New York to proceed with obligations related to FEMA emergency management programs for WTC cleanup.
2 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000170996
Proposal document prepared for the Mayor's Office of Emergency Management regarding lease and broker agreements.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000170923
Memorandum dated August 11, 1997, submitting a report and photographs of the proposed space for the Mayor's Office of Emergency Management.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168246
Excerpt from a report dated August 11, 1997, describing the exterior and condition of World Trade Center 7 for the Mayor's Office of Emergency Management.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173012
Detailed inspection report listing required repairs for doors, sprinklers, and electrical fixtures in the Mayor's Office.
Similarity score 0.938 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168718
Document outlining fire evacuation procedures and objectives for 7 World Trade Center.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Letter providing comments on submitted architectural plans for the Mayor's Office of Emergency Management.
Similar indexed content
NYC-WTC_000173529
Letter from law firm to City regarding administrative matter related to 7 World Trade Center.
Similar indexed content
NYC-WTC_000170996
Proposal document prepared for the Mayor's Office of Emergency Management regarding lease and broker agreements.
Similar indexed content
Similar indexed content
NYC-WTC_000168246
Excerpt from a report dated August 11, 1997, describing the exterior and condition of World Trade Center 7 for the Mayor's Office of Emergency Management.
Similar indexed content