Letter re: noise levels for generator room, Mar 1998

Machine-extracted title · confidence 90%

Letter submitting noise level data and comments regarding the 23rd floor emergency generator room in response to OEM requirements.

NYC-WTC_000167727–000167728

Folder label: “Mayor's Office of Emergency Management®Emergency Generator Noise

Page image
Scanned page image, NYC-WTC_000167727
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OKO. ;c zi^'/'ANE? HaYIEE CGEEE;.L wu.kk 0002

Shen March 10, 1998 I Milsom Sc Wilke ieCMNOLOOV CONSULTANtS HTEUSCQWMUMlOA'naNS, i UDIOUBUAL a ACOUSICS ‘.17 Fifth Avenue, New Yoik NY >0056 1212) 725.fi«00 Fax !212) Mr Joseph Aliotta Swanke Hayden Connell Architects 295 Lafayette Street New York, NY 10012

Re. Mayor's Office of Emergency Management Emergency Generator Noise

Dear Joseph,

We submit the following information and comments regardi; the expected noise level outside the T'' floor emergency generator room in res; .nse to the March 4, 1998 letter from Silverstein Properties..

Noise Control Treatments

The partitions enclosing the generator room shall ct , .sist of 3 5/8" metal studs with three (3) layers of 5/8" gypboaid on eac i side and full depth insulation within the smd cavities, all extending slab i> slab.

The generators shall be mounted on spring vibratio isolators selected to / provide minimum 2” static deflection

High efficiency hospital grade mufflers shall be provi led on each generator.

Noise Transmission Analysis

Based on measured generator noise levels at other ini lallations with similar sized generators, the noise level inside the generator rt: m when both engines operate will be about 115 dB A

The generator room partition constniction described i ove has an acoustical rating of STC-60 and is thus capable, m simplified erms, of stopping ox containing roughly 60 dBA of noise.

Therefore, with a source level of 115 dBA insid ; the room the noise transmitted to surrounding spaces will be reduced to > 5 dBA (115 minus 60 equals 55), or an equivalent Noise Criteria level of? C-SO to 55.

NEW YORK • W .A i 1 i 1 N C T O N , n C • FL0 I D h • CHICAGO • I 0NC K0N C • KV A A LU ,M P IJ L

NYC-WTC_000167727

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000167727Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000171246 · Box 7DCAS

Engineering firm report detailing noise criteria calculations for emergency generators in the Mayor's Office of Emergency Management space.

Filed in the same folder

NYC-WTC_000138209

Archival folder label for Department of Environmental Protection forms related to World Trade Center activities from 1996 to 2001.

Similar indexed content

Compare copies and versions →