SWANKE HAYDEN CONNELL ARCHITECTS
Fax Message
Rc Fjom
Maydr's Office Of Emergency Management Joseph J Aliotta
Emer^ncy Operations Ctnur-7 tVorU Trade Center Nq, Pagw
' 3376A 3
I Dale Tlnie
' 01/28/98 (Wed) 1:25PM
Outiibutton: (Pleaw deliver to person(s) Indicated by
Silverstein Properties, lac. (212) 732-1207 DCAS/DRES (212)669-3640 OEM (211)442-1815/9266
O Ms. C^ahenneGilibeiti |fi4lfr;Ktep Domingue! Y Mr. Piuriclt Ronen
O Mr. Ch Cbu (212) M7-0067 C Mr. vinldui Cwaenola C Mr. Jerome M. Hsuer
EssentlaiTecliiiologies poi) 738-1026 Coiantini Associates (212) 615-3700 Shan Mitsom (212) 725-0864
0 Ms. Merrily ?6wtll O Ml. Michael Mayfanuni O Mr. Eraeei J. Schinner
0 Mt. Roben Slavik
BFl (212)679-2201 RSA (212)633-1612 SHCA
0 Mr RCB Willard > O Mr. Robert Schwaiu 0 Mr. Cari Meinherilt
O Mr. Rpn Cocuzzs Q Mr. John Vandc Hwee
Messufie \
Attached: please find the consultant proposal for security by Vikonics, Inc. dated 01/27/98 for your review and approval.
A comparison of this proposal and the sample proposal given to Vikonics is as follows;
Item #1: i Vikonics will not produce a report outlining their design concepts in response lo development of a program
I by working with OEM. It appears Vikonics will produce a schematic design directly for your review and
approval. Vikonics needs to clarify whether their Bill of Materials will also include estimates of
construction costs associated with equipment not supplied by Vikonics.
Item it2;. Vikonics needs to clarify whether they will provide an outline specification or whether the Bill of Materials
will provide sufficient descriptive security design information for OEM and the SHCA design team to
review and coordinate the security equipment
ltem/^3,4^5: Vikonics to clarify that device matrix indicated is a foil security hardware schedule. No mention is given to
foil security specifications describing the required performance, function and intent of systems to be
I procured; description of work; installation p^ormance and quality; coordination of work by others; etc.
Item #7:, Vikonics makes no reference to punch listing and testing of system. No reference to as-built drawings
provided to OEM at end of project.
This proposal is specifically based upon the fact that Vikonics will be the only bidder and the only security expert on
board to determine Whether the design and equipment provided is of acceptable quality in comparison to the accepted
bid. Should OEM proceed with this course of action, the purchase order should be carcfiilly worded in terms of expected
quality, pjerformance, testing, warranty, service contract, etc.
Please review die aoove comments and die attached proposal and provide SHCA with your comments and direction.
Upon your review, comments and approval, SHCA will retain Vikonics as an consultant.
SHCA topics forward to hearuvdBMWrttyyMllMMteliawiM^
$««nta Hayden Conedl Ltd.
295 Urfayette Sireei, New York. New Yodt lOOU
(212) 216-9696. Fxx(212) 219-0059
W-'MTeiAlOemOoaalFaxiOlst Fax-8acumy 01-2S-9«,Doc