4.4:2 Elevators i 1
Water damage to elevators and elevators with advanced controls were discussed by the Mechanical Working Group.
The predominant reasons elevators are not usable during erhergencies are power failure and damage due to water. Their mechanical systems are often times shut down by water that penetrates elevator shafts. To encourage the development and use of drainage systems to catch H sprinkler and fire hose runoff in elevator shafts and near elevators, the Task Force recommends excluding components of these systems from being counted as "fixture units."
The mechanical group reviewed ways in which elevator controls could be engineered for more effective use in emergency situations. However, much like the evacuation group's discussion of "Phase HI" elevators, the emerging technology is still at the research and development stage. No satisfactory conclusions could be made.
Recommendation 17. Exclude floor drains for elevator vestibule and shafts from being counted I as fixtures in calculating normal waste water pipe capacity. I t
4.4.3 Heating, Ventilation and Air Conditioning (HVAC) Due to heightened security concerns, or the increased likelihood of an attack on building occupants through the use of HVAC systems, the mechanical group decided that even though air intakes for these systems are typically located above grade, that a standard should be set to require this practice. It was determined that air intakes should be located at least 20' above grade t. in all new construction and not in proximity to exhaust discharges of off street loading bays. 1 I HVAC systems can be designed to serve entire buildings or individual tenant spaces. Both design approaches are currently used in New York City and are allowed under current Building Code. The Mechanical Systems Working Group discussed, at the suggestion of FDNY representatives, the issue of fire spreading through a system's ductwork. It was pointed out that individually planned systems rely less heavily on ducts passing through other tenant occupied spaces than do centrally planned systems, theoretically lessening the spread of fire. The group agreed that only allowing the use of individually planned systems, which would not be economically viable, was not appropriate. It did suggest making the inspection of fire dampers a controlled inspection item, to enhance the enforcement of the current code. I \ No recommendations were made regarding the use of HVAC systems to defend against biological-chemical attack due to the lack of practical, cost effective systems at this time. ! ! Recommendation 18. Require air intakes in all new construction to be located at least 20' above grade and away from exhaust discharges or off street loading bays. I 19. Require controlled inspections of HVAC fire dampers in newly constructed I I occupancy group E buildings.
1 I Page 26 WTC Building Code Task Force February 2003 Findings and Recommendations
NYC-WTC_000166512
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000143746
Letter summarizing real estate industry comments on draft EPA guidance for building air protection environments.
1 shared non-person entities · similarity 0.942
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141695
Section of an environmental assessment describing existing physical conditions and construction impacts at the World Trade Center site.
4 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164903
Forwarded programmatic agreement documentation addressing post-disaster building cleaning procedures and eligible building list for recovery efforts.
2 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000141585
Map showing the condition of buildings at the World Trade Center site as of September 21, 2001.
9 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164098
Distribution of materials provided at January 15, 2002 WTC contractor health and safety meeting.
4 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000093788
Fax transmittal from the Mayor's Office regarding a March 2002 meeting with the building group.
2 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000168718
Document outlining fire evacuation procedures and objectives for 7 World Trade Center.
3 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150931
Cover fax from the Mayor's Office forwarding DEP documents regarding exterior clean-up to be reviewed before a meeting with building owners.
2 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000173475
Letter providing comments on submitted architectural plans for the Mayor's Office of Emergency Management.
2 shared non-person entities · 1 shared topics · similarity 0.936
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153468
Page containing illegible text and a document identifier for the EPA Inspector General series.
6 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000165271
Engineering drawings and specifications for replacing a high-pressure water line under the Lincoln Tunnel contract.
1 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000143354
Fragmented text containing only a reference number and unreadable characters from the DEP Box 06 collection.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Cited alongside this record in an Ask answer
NYC-WTC_000146129
Correspondence from NYC Corporation Counsel providing comments on excerpts of a draft EPA evaluation report regarding the WTC response.
Cited alongside this record in an Ask answer
NYC-WTC_000095781
Part III of a permit application dated January 10, 2006 regarding health and safety for remediation at 30 West Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label from the Office of the Mayor for World Trade Center records, identified as Folder 0139.
Cited alongside this record in an Ask answer