1. Do not flush through hydrants.

2. Submit details of method to be used to Engineer for approval.

3. Flush through size pipe and at flow rates as follows:

Size Pipe Size Flush Pipe Rate of Flow

6" 4" 750 gpm

4. Furnish and operate an approved type pitot gauge for checking flow rates.

5. Total flow through any pipe length shall be at least twice the volumetric capacity of that length, measured from the time the required flow rate is attained.

H. HYDROSTATIC TEST

Subject the entire piping system installed under this Con­ tract, including all parts and appurtenances, to a hydrosta­ tic test of not less than 200 psi or 50 psi in excess of maximum' static pressure, whichever is greater for a period of two hours. Leakage shall not exceed two quarts per hour per 100 pipe joints irrespective of pipe diameter. Further- more such leakage shall be distributed over all joints in the test section. If the leakage occurs in fewer than 1/3 of Ithe total number of joints, the installation will be considered unsatisfactory and necessary repairs will be required .

I. PURITY TEST

Have sterilization and test for purity of water in the en­ tire piping system, including all parts and appurtenances, and portions of lines de-watered in the performance of the Work, performed by an approved independent testing labora­ tory which shall furnish to the Engineer a certificate cer­ tifying conformance with the purity standards of the City of New York.

J. Obtain written approvals of the purity test from the City of New York and file original copy of said approval with the Engineer.

NYC-WTC_000165285

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165285Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165268 · Box DEP Box 44

A cover sheet or index page for documents related to the West 39th Street contract involving the replacement of infrastructure.

Filed in the same folder

NYC-WTC_000165112 · Box DEP Box 44

Construction specifications document detailing foundation requirements for the World Trade Center river water intake system relocation project.

Similar indexed content

Compare copies and versions →