← Document results/DEP Box 44/WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES
Document / 132 pages

Foundation Specifications for WTC River Intake Relocation

Machine-extracted title · confidence 95%

Construction specifications document detailing foundation requirements for the World Trade Center river water intake system relocation project.

NYC-WTC_000165112–000165243

Folder label: “WORLD TRADE CENTER - RELOCATION OF RIVER WATER INTAKE LINES & PUMP STATION ELECT. POWER & COMM. LINES

Page image
Scanned page image, NYC-WTC_000165168
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Batter^^Bark. City Commercial.Center Bldg. ’B’ WTC River Water Intake System Relocations

60" dia. line March 15 thru Nov, 15 20" dia. line - Nov. 15 thru March 15 1.07 EXISTING STRUCTURES AND UTILITIES A. The Subcontractor shall use utmost caution and proper care in the prosecution of the Work to assure the stability of the existing bulkhead walls.. Marginal St., Sewer Outfalls, World Trade Center cooling water facilities, PATH Tubes and other structures, utili­ ties, installations and services. In the event that the Contractor determines that any such structure or installations have been damaged as a result of the Subcontractor's operations, repairs or replacement shall be performed to the satisfaction of the Contrac­ tor and the Owners of the property, all at the sole cost and expense of the Subcontractor. 1.08 RULES FOR WELDING AND BURNING A., The Subcontractor shall secure a copy of the "Rules for Welding and Burning" for the Department of Ports and Terminals. These rules cover requirements for safety in connection with Work on waterfront struc- tures. The Subcontractor shall comply with fchese rules at all times and keep a copy available at the site for use of his employees and others. 1.09 FIRE ACCESS TO FIRE APPARATUS A, The Subcontractor shall not interfere with access to hydrants and fire alarm boxes. In no case shall the Subcontractor's material or equipment be withi.n twenty (20) feet of a hydrant or fire alarm, box. 1.10 EQUIPMENT AND MATERIALS A, If products and materials are specified or indicated on the drawings for a specific item or system, the Subcontractor shall use those products or materials. If products and materials are not listed in either of the above, use first class products and materials, subject to approval of shop drawings. B. All products and materials shall be new, clean, free of defects and free of damage and corrosion.

Mechanical Special Conditions 15010-8

NYC-WTC_000165168

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000165168Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165064 · Box DEP Box 44

Request documentation regarding the relocation of river water intake lines and pump station utilities at the World Trade Center.

Filed in the same folder

Compare copies and versions →