NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 43/E-mails 2002 M. Gilsenan
Document / 3 pages

Overtime waiver request follow-up for DEP staff, March 13, 2002

Machine-extracted title · confidence 93%

Correspondence urging submission of approved waiver requests for employees to earn paid overtime during cleanup operations.

NYC-WTC_000164266–000164268

Folder label: “E-mails 2002 M. Gilsenan

Page image
Scanned page image, NYC-WTC_000164267
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

THE CITY OF NEW YORK DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF ENVIRONMENTAL COMPLIANCE ASBESTOS CONTROL PROGRAM

AIR MONITORING AND ANALYSIS SERVICE CONTRACT

SCOPE OF WORK

A. Introduction

All work performed under this contract must be in compliance with all applicable, relevant, and appropriate regulations, including but not limited to those of the United States Environmental Protection Agency (USEPA), the United States Department of Labor Occupational Safety and Health Administration (USOSHA), the New York State Department of Labor (NYSDOL), the New York State Department of Health Environmental Laboratory Approval Program (ELAP) and the New York City Department of Environmental Protection (NYCDEP). The services required must be provided during regular business hours and weekends. The number of samples and other tasks are estimates for bidding purposes, with no minimum guarantee. This contract will be awarded to the lowest responsive and responsible bidder. The items listed on the bid sheet reflects the types of services required. A pre-bid conference shall be scheduled at the DEP office, at 59-17 Junction Boulevard, 8* floor.

B. Contract Term

This contract shall be in force for 120 consecutive calendar days from the NYC DEP commencement date.

C. Qualification

The laboratory must be in compliance with the National Environmental Laboratory Accreditation Conference (NELAC) standards and have certification by ELAP in the category of Airborne Asbestos by Transmission Electron Microscopy (TEM). Certification must be maintained for at least 6 consecutive proficiency testing rounds. Air monitoring technicians must possess valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air monitoring for at least 2 years and conducted final clearance inspections on at least 50 asbestos abatement projects. A minimum of 5 APST must be available to conduct air monitoring. Proof of qualifications must be presented to NYC DEP upon request.

Sampling equipment must be in sufficient quantity to provide the turnaround time on each project. At a minimum the following equipment are required: air-sampling pumps (electric and battery operated) with flow rate capacities of 2 to 10 liters per minute, rotometers, mixed cellulose ester sample filters having pore size of 0.45um and electrical generators .

1

NYC-WTC_000164267

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000164267Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →