NYC 9/11 Public Portal Document
.Before beginning aggressive air sampling, a 1 horsepower electric leaf blower shall be used to direct exhaust
air against walls, ceilings, floors and other surfaces. This shall continue for at least five minutes per 1;
square feet of floor. When directing the exhaust, caution shall be taken to minimize disturbance and potential
damage to furnishings and personal belongings.
Personal protective equipment including disposable clothing, gloves, and respirators shall be worn during
aggressive air sampling activities.
HVAC systems shall be shut down or isolated locally during aggressive air sampling.
Room and window air conditioners shall not be operated during aggressive air sampling.
Leaf blowers shall not be employed for modified aggressive air sampling.
All other procedures are identical for aggressive and modified aggressive air sampling, unless otherwise noted.
At least one 20-inch fan shall be placed in the center of each room sampled. One fan per 10,' cubic feet of
room space shall be used. The fans shall be operated on slow speed and pointed toward the ceiling. The fans
shall run for at least 15 minutes prior to the start of sampling. The fans shall operate continuously throughout
sampling and shall not be turned off until sampling is completed.
For studio apartments 3 air samples shall be collected. For 1-bedroom apartments and above, 5 air samples
shall be collected. Sampling equipment shall be placed in living areas and away from obstructions. The
sampling cassette must be placed on a tripod, not taped to existing surface and should be directed downward at
a 45 degree angle.
Common spaces will be sampled without the use of forced air devices (fans, leaf blowers etc). For small
spaces, less than 160 square feet, 3 samples will be collected. For large spaces greater than 160 square feet and
less than 25,000 square feet 5 samples will be collected. For spaces greater than 25,000 square feet, 1 sample
will be collected for each 5,000 square feet. Sampling equipment shall be placed away from obstructions. The
sampling cassette must be placed on a tripod directed downward at a 45 degree angle and not taped to existing
surfaces.
Air samples will be collected in accordance with the procedures specified in NIOSH 7400 Method. The flow
rate for collection of air samples shall be at least 10 liters per minute and no more than 15 litem per minute. Air
sampling cassettes need to be monitored to ensure that the filters do not develop dark spots that would indicate
clogging. The minimum sampling volume required is 3600 liters. If clogging develops then the cassette must
be changed.
4 of 5
NYC-WTC_000163308
OCR can misread numbers and units. Confirm readings against the page image before using them.