Monitoring contractor specifications review, 114 Liberty, February 2003

Machine-extracted title · confidence 90%

Request for review of monitoring contractor specifications for air sampling, including sampling methodologies, limits of detection, and clearance criteria, with reference to prior…

NYC-WTC_000162815–000162821

Folder label: “E-mails 2003 M. Gilsenan

Page image
Scanned page image, NYC-WTC_000162820
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ww Parameter Asbestos in air Lead in settled dust Clearance Level 0.0009 f/cc PCMe <25 gg/tf Note Primary clearance level Primary clearance level Dioxin in settled dust <4rig/rn Primary clearance level Fibrous glass in air <0.01 fi'cc Secondary clearance level Crystalline silica in air 0.5gg/m^ Secondary clearance level PAHs in settled dust <0.15 mg/m^ Secondary clearance level

2. Cleaning shall not be considered complete unless the primary clearance levels are achieved. The apartment will be re-cleaned and retested if the primary clearance levels are not achieved. These clearance levels may be re-evaluated and revised if determined necessary based on field conditions and analytical limitations. Secondary clearance levels shall be considered in determining the need for additional cleanup, however failure to meet the secondary clearance levels does not automatically trigger the re-cleaning. In the event re-cleaning is required, re-sampling shall be performed immediately upon completion of the cleaning.

5 of 6

NYC-WTC_000162820

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000162820Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →