NYC 9/11 Public Portal Document
4/25/2003 PASC- Certificate ofAnalysis Page 1 of 9
Method Method 3rd
Client fD: Blank Blank Floor-01
Lab No.: 013656 03 013656 03 % 013657 03
PSC-Reading Lab ID: R03040083-01
Date Sampled: 29-Mar-2003 29-Mar-2003 Recovery 29-Mar-2003
Component MDL Units M. Spike
Unvalidated
Total Tetrachlorodibenzofurans pg <1.2 1100 <2.1
Total Pentachlorodibenzofurans 5.9 5700 <2.9
Total Hexachlorodibenzofurans » 3.0 9700 <1.3
Total Heptachlorodibenzofurans <4.4 4800 <3.6
Octachlorodibenzofuran 12 4400 4.9
Total Tetrachlorodibenzo-p-dioxins <1.4 960 <2.5
Total Pentachlorodibenzo-p-dioxins <1.6 2500 <2.0
Total Hexachlorodibenzo-p-dioxins tt
4.4 7600 <2.1
Total Heptachlorodibenzo-p-dioxins 7.3 2300 5.3
Octachlorodibenzo-p-dioxin <12 5000 34
Internal Recoveries %
2,3,7,8-T4CDF-13C12 74 73 76
2,3,7,8-T4CDD-l3CI2 82 81 85
1,2,3,7,8-P5CDF-13C12 83 85 81
I,2,3,7,8-P5CDD-13C12 96 97 85
1,2,3,4,7,8-H6CDF-13CI2 103 95 99
1,2,3,6,7,8-H6CDD-13C12 101 98 87
1,2,3,4,6,7,8-H7CDF-13C12 107 103 92
1,2,3,4,6,7,8-H7CDD-I3C12 HI 114 84
OCDD-13CI2 102 107 66
2,3,7,8-CI4-Dibenzofuran (DB5) pg <1.2 1100 108 <2.1
2,3,7,8-C14-Dibenzo-p-dioxin <1.4 960 96 <2.5
1,2,3,7,8-CI5-Dibenzofuran 2.3 2700 IIO <2.9
2,3,4,7,8-C15-Dibenzofuran 3.6 2900 118 <3.0
1,2,3,7,8-C15-Dibenzo-p-dioxin <1.6 2500 102 <2.0
1,2,3,4,7,8-C16-Dibenzofuran <2.7 2500 98 <1.2
1,2,3,6,7,8-CI6-Dibenzofuran <2.7 2400 96 <1.2
2,3,4,6,7,8-CI6-Dibenzofuran 3.2 2500 99 <1.4
1,2,3,7,8,9-CI6-Dibenzofuran <3.4 2300 94 <1.5
l,2,3,4,7,8-CI6-Dibenzo-p-dioxin <2.8 2600 104 <2.1
l,2,3,6,7,8-CI6-Dibenzo-p-dioxin 4.4 2500 101 <2.1
1,2,3,7,8,9-C16-Dibenzo-p-dioxin <2.7 2500 98 <2.0
1,2,3,4,6,7,8-CI7-Dibenzofuran <4.0 2500 99 <3.2
1,2,3,4,7,8,9-C17-Dibenzofuran <4.8 2300 94 <1.7
l,2,3,4,6,7,8-CI7-Dibenzo-p-dioxin 7.3 2300 92 5.3
1,2,3,4,6,7,8,9-C18-Dibenzofuran 12 4400 88 4.9
tl
l,2,3,4,6,7,8,9-C18-Dibenzo-p-dioxin <12 5000 100 34
2,3,7,8-TCDF (DB225) pg
Internal Recoveries %
2,3,7,8-TCDF-13C12
Client:Philip Analytical Services Inc ProjectJLC Environmental
NYC-WTC_000155044
OCR can misread numbers and units. Confirm readings against the page image before using them.