also taking breaks at this adjacent hotel for another 3 hours a day. He is a smoker.

The levels of outdoor asbestos exposure during the first 2.5 weeks exposure is estimated to be 500 s/mL. He is both in the open air and in confined spaces. This level is 100 times the highest level found by the HP Environmental study in passive conditions in two buildings damaged but still standing near the World Trade Center.^ EPA did not have monitoring equipment in confined spaces, although it did eventually on the perimeter of Ground Zero. OSHA does not appear to have tod personal monitoring equipment on firefighters, only stationary monitoring in open areas around Ground Zero.

The level of outdoor asbestos exposure is estimated to be 0.50 s/mL during file second 2.5 weeks, al level consistent with many EPA readings at Ground Zero during the first month. Actually, there would have been a gradual decline of the initial 500 to 0.50 s/mL levels over the month, but the 2-time period per exposure level is convenient for calculations.

From Table 2, the asbestos level inside the contaminated building near Ground Zero is estimated to be 10 s/mL, midway between the “passive” conditions tested in the high-exposure building near Ground Zero, and the level estimated for cleaning out a storage room.

s/mL X time period (years) total dose (s-year/mL) 500 (16/365)x(12C4) 10.2740 0.50 (15/365)x(12j24) 0.0103 10 (30/365)x(12/24) 0.4110 total dose (cumulative exposure) 10.6952

His increased risk is 1 in 30 for both mesothelioma and limg cancer. The firefighter has a risk of over 2/1000 for developing asbestosis, and would probably have abnormal radiological findings of the chest.

LAB METHODS FOR ASBESTOS, WAYS OF REPORTING RESULTS

This section may be helpfill for interpreting the many different ways that asbestos levels are measured analytically, and also the many different ways these levels are reported.

PCM methods for air and bnlk samples

The older method fer measuring asbestos in air was by phase contrast microscopy (PCM). PCM measurements are reported as either structures/milliliter ( s/mL) or fibers/milliliter (f/mL). PCM cannot detect fibers and structures with diameters smaller than 0.5 micrometers (0.5 pm or 0.5 um). PCM cannot distinguish asbestos fibers from non-asbestos fibers.

Thus, TEM measurements will give higher readings of asbestos fibers than PCM measurements if most of the fibers are actually asbestos, and if the asbestos fibers themselves have a significant fraction that are smaller than 0.5 pm. In WTC dusts, all the data I have seen indicates that TEM measurements are higher than PCM measurements of the same sample.

- 15-

NYC-WTC_000154668

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000154668Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →