NYC 9/11 Public Portal Document
also taking breaks at this adjacent hotel for another 3 hours a day. He is a smoker.
The levels of outdoor asbestos exposure during the first 2.5 weeks exposure is estimated to be
500 s/mL. He is both in the open air and in confined spaces. This level is 100 times the highest
level found by the HP Environmental study in passive conditions in two buildings damaged but
still standing near the World Trade Center.’® EPA did not have monitoring equipment in
confined spaces, although it did eventually on the perimeter of Ground Zero. OSHA does not
appear to have bad personal monitoring equipment on firefighters, only stationary monitor ng in
open areas around Ground Zero.
The level of outdoor asbestos exposure is estimated to be 0.50 s/mL during he second 2.5 weeks,
al level consistent with many EPA readings at Ground Zero during the first month. Actually,
there would have been a gradual decline of the initial 500 to 0.50 s/mL levels over the month, but
the 2-time period per exposure level is convenient for calculations.
From Table 2, the asbestos level inside die contaminated building near Ground Zero is estimated
to be 10 s/mL, midway between the '"passive” conditions tested in the high-exposure building
near Ground Zero, and the level estimated for cleaning out a storage room.
sZmL X time period (years) total dose (s-year/mL)
500 (15/365)x(12i24) 10.2740
0.50 (15Z365)x(12Z24) 0.0103
10 (30Z365)x(12J24) 0.4110
total dose (cumulatve exposure) 10.6952
His increased risk is I in 30 for both mesothelioma and lung cancer. The firefighter has a risk of
over 2/1000 for developing asbestosis, and would probably have abnormal radiological findings
of the chest.
LAB METHODS FOR ASBESTOS, WAYS OF REPORTING RESULTS
This section may be helpful for interpreting the many different ways that asbestos levels are
measured analytically, and also the many different ways these levels are reported.
PCM methods for air and bulk samples
The older method fijr measuring asbestos in air was by phase contrast microscopy (PCM). PCM
measurements arc reported as either structures/milliliter ( s/mL ) or fibers/milliliter (f/mL). p ^M
cannot detect fibers and structures with diameters smaller than 0.5 micrometers ( 0.5 pm or 0.5
um ). PCM cannot distinguish asbestos fibers from non-asbestos fibers.
Thus, TEM measurements will give higher readings of asbestos fibers than PCM measurements
if most of the fibers are actually asbestos, and if the asbestos fibers themselves have a significant
fraction that are smaller than 0.5 pm. In WTC dusts, all the data I have seen indicates that TEM
measurements are higher than PCM measurements of the same sample.
- 15-
NYC-WTC_000140273
OCR can misread numbers and units. Confirm readings against the page image before using them.