NYC 9/11 Public Portal Document
square millimeter.... [9/17/01 "Daily Summary"]
9/18 In the recent rounds of ambient air sampling, 21 samples were 110.24 s/mm2 - MURRAY & CHURCH ST., 3 blocks
collected and analyzed from 11 monitoring sites (one new NNE of Ground Zero perimeter
monitor was has [s/c] been added). Four of these samples had
157.48 s/mm2 - WEST ST & VESEY ST.. NW corner
levels of asbestos that were marginally above the level that
of Ground Zero perimeter
EPA is using as a level of concern. EPA continues to advise
personal protective equipment for the emergency response overload - FULTON & CHURCH ST., east perimeter
workers. [9/18/01 "Daily Summary". Note no warning for of Ground Zero
residents.]
overload - LIBERTY ST. & CHURCH ST., SE
"We are very encouraged that the results from our monitoring perimeter of Ground Zero
of air quality and drinking water conditions in both New York
and near the Pentagon show that the public in these areas is
not being exposed to excessive levels of asbestos or other
harmful substances," Whitman said. A Given the scope of the
tragedy from last week, I am glad to reassure the people of
New York and Washington, D.C. that their air is safe to breath
and their water is safe to drink," she added. ... Thus far, from
50 air samples taken, the vast majority of results are either
non-detectable or below established levels of concern for
asbestos, lead and volatile organic compounds. The highest
levels of asbestos have been detected within one-half block of
ground zero, where rescuers have been provided with
appropriate protective equipment. ... [EPA press release,
9/18/01]
9/19 EPA's most recent rounds of air samples from 11 fixed 149.61 s/mm2 - WEST ST & WARREN ST., 4 blocks
monitoring sites in and around the "hot zone" were below the N of Ground Zero perimeter
EPA limit for asbestos. This bring the total number of samples
122.48 s/mm2 - MURRAY & CHURCH ST., 3 blocks
taken from fixed monitors to 68.... [9/19/01 "Daily Summary"]
NNE of Ground Zero perimeter
The majority of EPA's most recent rounds of air samples from
overload - NORTH END AVE & VESEY ST., 3
11 fixed monitoring sites in and around the "hot zone" were
blocks NW of Ground Zero perimeter
below the EPA limit for asbestos. Out of 25 samples analyzed
yesterday, one sample did indicate a slightly elevated level of overload - FULTON & CHURCH ST., at east
asbestos from a monitoring station located one block from perimeter of Ground Zero
ground zero...... [9/20/01 "Daily Summary"]
overload - SOUTH END AVE & ALBANY ST, 3
blocks SW of Ground Zero perimeter
overload - WEST ST & ALBANY, 2 blocks S of
Ground Zero perimeter
9/20 None of the 29 samples analyzed for asbestos over the last
two days showed detectable levels of this chemical....
[9/21/01 "Daily Summary"]
9/21 In the most recent sampling rounds, EPA analyzed 13 samples 78.74 s/mm2 - WEST ST & WARREN ST., 4 blocks
for asbestos. Five of the 13 samples were above the 70 s/mm^ N of Ground Zero perimeter
structures per square millimeter standard that EPA uses to
overload - GATEWAY PLAZA PARK AREA, 3 blocks
clear schools for re-occupation after asbestos removal. All
W of Ground Zero perimeter
were taken in or in very close proximity to the excluded area
around the World Trade Center.... [9/22/01 "Daily Summary"] 78.74 s/mm2 - THIRD PLACE & BATTERY PL -
WATERSIDE, 6 blocks SW of Ground Zero
... MONITORING EFFORTS CONTINUE TO SHOW SAFE
perimeter
DRINKING WATER, AIR ... U.S. Environmental Protection
Agency (EPA) Administrator Christie Whitman announced
today that the most detailed results to date of ongoing
monitoring of drinking water in New York City provide
additional reassurance that residents and people who work
10
NYC-WTC_000153789
OCR can misread numbers and units. Confirm readings against the page image before using them.