NYC-WTC_000155990
Detailed procedures for interior remediation at 125 Cedar including EPA air monitoring specifications.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Resident requests DEP cleaning and monitoring at 125 [name] following WTC collapse debris accumulation.
NYC-WTC_000153551–000153556Folder label: “WORLD TRADE CENTER 125 CEDAR”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Cleaning Procedures For 125 Cedar Street
(7) A separate worker and waste decontamination enclosure system in compliance with Title 15, Chapter 1 of the RCNY shall be installed at the entrance to each work area. Each work area shall entail isolating three floors at 125 Cedar Street simultaneously. More than one work area may be established. Work shall proceed from the penthouse down to the first floor. The use of a remote decontamination enclosure system installed on the second floor for use at each work area (except first floor and basement) may be acceptable. Prior approval must be received from the NYC DEP for decontamination enclosure system placement and phasing of clean-up activities.
(8) An entry/exit log in compliance with the requirements set forth in Title 15, Chapter 1 of the RCNY shall be maintained in the clean room. The site supervisor shall maintain an activity log.
(9) Initially, the interior of the elevator shaft, including the top of the elevator car and the elevator pit, shall be HEPA vacuumed and wet wiped to allow for the use of the elevator during the clean up. Once the clean up throughout the building is complete, the elevator shaft, including the top of the elevator car and the elevator pit, shall be re-cleaned prior to clearance air monitoring.
(10) Isolation barrier locations (i.e.: wall or ceiling penetrations, windows, vents, doors, etc.) shall be HEPA vacuiuned and wet wiped prior to installing two-layers of 6-mil polyethylene sheeting and sealed with tape. Terraces, window wells, and window guards that are accessible from the interior shall be cleaned.
(11) Negative pressure ventilation equipment shall be installed and operated continuously 24 hours per day during all clean-up activities. Equipment shall run continuously until clearance air monitoring. A minimum of one air change every 15 minutes shall be provided. When ducting to the outside is not possible, a second negative air unit compatible with the primary unit may be connected in series.
(12) A staging area shall be established within each unit. The area shall be cleaned (wet-wiped and HEPA vacuumed) and covered with a layer of 6-mil polyethylene sheeting. The staging area shall be used for cleaning the surfaces of moveable items.
(13) All debris and/or dust shall be misted and double bagged. Accumulation of water is prohibited. Water misting shall be sufficient to wet the material without water accumulations. Caution shall be taken to avoid wetting items that may be damaged by wet methods. An encapsulating agent shall not be applied. Once all surfaces have been wet wiped and HEPA vacuumed a second cleaning shall be performed. Surfaces include but are not limited to walls, floors, ceilings, ledges, windowsills, trims, appliances, equipment, personal items, and furnishings.
(14) Surfaces that may not be wet wiped shall be HEPA vacuumed three times or disposed as ACM waste. Disposal of material may not occur without prior authorization by the building owner and/or tenant, as applicable. Items identified by tenants for cleaning that caimot be cleaned shall be immediately brought to the attention of NYC DEP. NYC DEP will contact the tenant or tenant representative to resolve the issue. Any agreement to dispose the item(s) must be received in writing from the tenant.
2 of 6
NYC-WTC_000153552
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000155990
Detailed procedures for interior remediation at 125 Cedar including EPA air monitoring specifications.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155880
Document outlining requirements for a consultant to provide full-time asbestos air monitoring during the interior cleaning of 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155872
Application requesting approval for a licensed contractor to clean debris and dust from the building's interior.
10 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗11 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000156006
Internal communication confirming receipt of Department of Health mold assessment report for 125 Cedar.
11 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107808
Permit application for asbestos abatement contractor to clean interiors of a building at 125 [name].
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000097106
Application for a permit to perform interior cleaning and asbestos abatement at 125 Cedar Street.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000096827
Document identified only by its archive reference number with no visible text content in the excerpt.
Cited alongside this record in an Ask answer
NYC-WTC_000148621
Memo outlining DEP activities including assessment and coordination with federal agencies for street and sidewalk cleaning.
Cited alongside this record in an Ask answer
NYC-WTC_000096907
Heavily redacted and degraded cleaning request form for 125 Manhattan apartment authorizing DEP cleaning and monitoring work with environmental protection provisions.
Cited alongside this record in an Ask answer
NYC-WTC_000096939
Faxed cleaning request form dated September 10, 2002, authorizing DEP cleaning and monitoring work at 125 Manhattan apartment under federal relief act authority.
Cited alongside this record in an Ask answer
Letter from DOHMH transmitting results of a July 2002 mold inspection at 125 Liberty Street.
Cited alongside this record in an Ask answer