NYC 9/11 Public Portal Document
including two from an indoor area. Quartz, calcite, and gypsum were reported for all of
these samples. Each of these was occasionally reported as a major constituent of the
material, i.e., estimated at 20% or higher. Twenty-six of these samples contained mica,
usually estimated as trace or less than 5% of the material. Portlandite was only noted in
two samples at trace levels, including the one indoor sample analyzed.
1. Association ofAsbestos and Synthetic Vitreous Fibers
Based upon the sampling results, it appears that SVF is likely to be found in settled surface
dust whenever asbestos is detected in the settled surface dust All of the six outdoor and
five common areas that had asbestos in settled surface dust also had SVF in the settled
surface dust (Table 9). Of the ten residences that contained asbestos in settled surface dust,
a little more than half also contained SVF. However, this does not hold true in areas
without asbestos, where the absence of asbestos does not indicate an absence of SVF. Of
the eight outdoor areas without asbestos in the settled surface dust, three contained SVF.
Similarly, SVF was found in approximately 25% of the common areas and in
approximately 36% of the residences without asbestos in the dust Although the presence of
asbestos in the dust seems to correspond to SVF, the absence of asbestos does not predict
or correspond to a presence or absence of SVF in settled surface dust, in either indoor or
outdoor areas of lower Manhattan.
2. Association ofAsbestos and Synthetic Vitreous Fiber Levels Outside of and l^thin
a Building
Outdoor settled surface dust was collected at 14 buildings in lower Manhattan. One
purpose for collecting outdoor dust was to determine if the contents of the outdoor dust at a
location would reflect the type of indoor dust In the case of fibers, there is little
correlation in the indoor and outdoor dust composition. High levels of outdoor SVF are
associated with both high and low indoor levels. The presence or absence of asbestos in
settled surface dust shows a similar lack of correlation. The outdoor settled surface dust
samples do not correspond with indoor dust composition for either group of fibers. This
lack of association could, in part, be due to whether and how frequent interiors and
exteriors had been cleaned.
In contrast, indoor levels of fibers in settled surface dust did seem to correspond within a
building. Buildings with elevated SVF levels in the common area tended to have elevated
levels in the residences. A similar pattern was seen between the two residences sampled in
the same building. For example, SVF was often found in both residences sampled within
the same building, or was absent in both residences. Within this limited data set, fiber
levels in one area of a building seem to weakly correspond with fiber levels in other areas
of the same building. However, none of these data represent total dust loading, only the
relative amount of fibers within the dust
27
NYC-WTC_000149729
OCR can misread numbers and units. Confirm readings against the page image before using them.