NYC 9/11 Public Portal Document
fiber counts greater than comparison areas above 59th Street were not elevated due to
either asbestos or SVF fibers.
There were 15 out of the 83 (18%) indoor areas in lower Manhattan with measurable
asbestos in the settled surface dust, 10 residences and 5 common areas (Table 9). Nine of
these residences were sampled aggressively (the air exhaust of the vacuum used for settled
dust sampling was used to stir up all dust into the air before an air sample was taken). Four
of these aggressively sampled residences had measurable fiber levels in air ranging from
0.001 free to 0.003 free. One residence was occupied and could not be aggressively
sampled. Air sampling at that location indicated <0.001 free by PCM analysis. Because the
levels found were within the range measured in the comparison areas above 59th Street, no
TEM or SEM re-analysis was performed on these air samples. Therefore the composition
of these fibers is unknown (i.e., asbestos, SVF, cellulose).
None of the common areas were aggressively sampled because all of these areas were
open to the public. Of the five common areas with some asbestos in the dust, three had
measurable levels of fiber in the air ranging from 0.001 free to 0.002 free. One area in
building 5 where there was not enough settled surface dust to sample had an airborne fiber
count of 0.002 f/cc. No TEM or SEM re-analysis was performed on these air samples, and
the composition of these fibers is unknown (i.e., asbestos, SVF, cellulose).
b. Outdoor Air
Six of the 14 lower Manhattan outdoor locations sampled had detectable levels of asbestos
in the settled surface dust, indicating a potential in these locations for asbestos fibers to
become airborne. Air sampling indicates three of the locations did not have detectable
fibers in the air (Table 9). The air samples from buildings 1,2, and 5 did have fibers
detected at levels from 0.001 free to 0.003 f/cc. Of the 15 locations where no settled
surface dust samples were taken, the majority of the results showed <0.001 free in the air,
with only 4 samples reported at the detection limit of 0.001 free. Because the levels found
were within the range measured in the comparison areas above 59th Street, no TEM or
SEM re-analysis was performed on these air samples, and the composition of these fibers
is unknown (i.e., asbestos, SVF, cellulose).
2. Minerals in Air
Air samples of different particulate sizes, representing inhalable (PM 100), thoracic
(PMIO), and respirable (PM4 and PM2.5) fractions were collected in selected building
locations. Not all size fractions were collected at every location. The samples were
analyzed by XRD for the same crystalline minerals seen in the settled surface dust samples.
Each of the four size fractions was collected with a separate sampling device. The PM 100
fraction collected particles with an aerodynamic diameter of 100 microns and lower. The
PMIO fraction collected particles with an aerodynamic diameter of 10 microns and lower
and so on. The results reported here are expressed as the mass of mineral per unit volume
of air or micrograms per cubic meter of air (gg/m?). Quantification of the minerals is not
exact due to variations in particle size as compared to the particle size used in the standard
24
NYC-WTC_000149725
OCR can misread numbers and units. Confirm readings against the page image before using them.