NYC 9/11 Public Portal Document
» M
____________________________________ 04/03/02 DRAFT: not for public release __________ ______________________ ______________
Ambient and Indoor Sampling for Public Health Evaluations of Residential Areas
Near World Trade Center, New York, New York (November 4 - December 11, 2001)
Resuits were compared to dust and air leveis found in homes iocated in "non-impacted" areas
and to indoor asbestos standards. At each sampied building, attempts were made to sampie in a
common area, two residences, and an adjacent outdoor location.
Dust-
If PLM was less than 1%*, confirmation by TEM was performed.________________________________
____________ If TEM was less than 1%, no further action was taken.______________________________
If TEM was greater than 1%, further action was taken._____________________________
If PLM was greater than 1%, confirmation by TEM was unnecessary and further action was taken.
Air:
If PCM was less than 0.003** f/cc, no further action was taken._____________________________________
If PCM was greater than 0.003 f/cc, confirmation by TEM was performed._____________________________
____________ If TEM was less than 0.01 f/cc, no further action was taken.______________________________
____________ If TEM was greater than 0.01 f/cc (did not occur), further action would have been needed.
If PCM Is greater than 0.01*** f/cc, confirmation by TEM was performed.
* A material is considered to be asbestos- wntsininQ rial If It contains more than 1% asbestos using the PLM method.
When asbestos was detected, only Chrysotile asbestos was found.
** 0.003 is the upper range (0.001 - 0.003) of background Indoor air fiber concentrations determined in non-Impaeted areas.
**♦ Asbestos clearance criteria. Rules of the City of New York. Title 15, Chapter 1.
Results for Asbestos in Air and Settled Dust
Building Asbestos in Asbestos In
Location Fibers In Air
Number Dust Dust Asbestos In Air
Residential Buildings In Lower Manhattan
Building 1
PLM [%1 TEM [%] PCM [f/cc] TEM [f/cc]
1 Outside ND Not Sampled 0.001 NA
1 Common Not Sampled Not Sampled <.001 NA
1 Rest ND Not Sampled 0.006 <.001
1 Res 2 ND Not Sampled <.001 NA
Building 1 Notes: PCM results at Res 1 exceeded 0.003 f/cc. Asbestos fibers were not detected In this sample by TEM analysis.
There was not enough material left to analyze the outdoor and residential dust samples by TEM.
Building 2
PLM [%] TEM [%] PCM [f/cc] TEM [f/cc]
2 Outside <1 1.2 0.003 NA
2 Common ND Not Sampled 0.005 <.001
2 Rest ND Not Sampled <.001 NA
2 Res 2 ND Not Sampled 0.002 NA
2 Window sni <1 <1 NA NA
2 Outside X 1.3 NA Not Sampled NA
Building 2 Notes: PEP Inspected and found asbestos-containing material In the outdoor location which was then professionally abated. ____
PCM results exceeded 0.003 f/cc In the common area. Asbestos fibers were not detected in this sample by TEM analysis.
There was not enough material left to analyze the indoor dust samples by TEM._________________________________
NYC-WTC_000149606
OCR can misread numbers and units. Confirm readings against the page image before using them.