NYC 9/11 Public Portal Document
04/03/02 DRAFT: not for public release
Ambient and indoor Sampling for Public Health Evaluations of Residential Areas
Near World Trade Center, New York, New York (November 4 - December 11, 2001)
Results were compared to dust and air levels found in homes located in "non-impacted” areas
and to indoor asbestos standards. At each sampled building, attempts were made to sample in a
common area, two residences, and an adjacent outdoor location. _____
i I ‘I
Dust: ! . .|
If PLM was less than 1%*, confirmation by TEM was performed.
If TEM was less than 1%. no further action was taken.
If TEM was greater than 1%, further action was taken. __________ ______
If PLM was greater than 1%, confirmation by TEM was unnecessary and further actlon was taken.
- -H -
Alr:
If PCM was less than 0.003** f/cc, no further action was taken. - 4______ +
If PCM was greater than 0.003 f/cc, confirmation by TEM was performed.
-T
If TEM was less than 0.01 f/cc, no further action was taken.
If TEM was greater than 0.01 f/cc (did not occur), further action would have been needed.
If PCM is greater than 0.01*** f/cc, confirmation by TEM was performed. ________ ______
• A material is considered to be asbestos-containing material if it contains more than 1% asbestos using thePLM method.
When asbestos was detected, only Chrysotile asbestos was found. _____ _______
*• 0.003 Is the upper range (0.001 - 0.003) of background indoor air fiber concentrations determined In non-impacted areas._____
”• Asbestos clearance criteria. Rules of the City of New York, Title 15. Chapter 1. J __________
Results for Asbestos in Air and Settled Dust
Asbestos in Asbestos In ' ™ Asbestos In
Location Fibers in Air
Number Dust Dust Air
Residential Buildings In Lower Manhattan
I 1 ■-
I
Building 1
4 --4-
PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] ----- 4
■ ■ -f - -
1 Outside ND Not Sampled J 0.001 NA
1 Common Not Sampled Not Sampled <.001 NA
1 Res1 ND Not Sampled 0.006 <.001 4 --
1 Res 2 ND Not Sampled ; <•001 NA
-- t
Building 1 Notes: PCM results at Res 1 exceeded 0.003 f/cc. Asbestos fibers were not detected in this sample by TEM analysis.___
There was not enough material left to analyze the outdoor and residential dust samples by TEM. ________
Building 2
PLM [%] TEM [%] PCM [f/cc] TEM [f/cc]
2 Outside <1 1-2 0.003 NA
I
2 Common ND Not Sampled 0.005 <.001
2 Res1 ND Not Sampled <.001 NA
r
- - 4 -
2 Res 2
2 Window Sill
ND
<1
Not Sampled
<1
0.002
NA
NA 41 p-
“ : . - . ---------
2 Outside X 1.3 NA Not Sampled NA ; ]
f-
Building 2 Notes: DEP Inspected and found asbestos-containing material in the outdoor location which was then professionally abated.
PCM results exceeded 0.003 f/cc in the common area. Asbestos fibers were not detected in this sample by TEM analysis. I'
There was not enough material left to analyze the Indoor :dust samples ■ by TEM.
I ■ ;
!
----------------- r- -*■ -- . t
I ; ; : .. -- -i-
Building 3
PLM [%] TEM [%] PCM [f/cc] TEM [f/cc]
3 Outside Not Sampled Not Sampled <.001 NA
NYC-WTC_000139702
OCR can misread numbers and units. Confirm readings against the page image before using them.