NYC 9/11 Public Portal Document
ASBESTOS and OTHER FIBERS by PCM; METHOD 7400. Issue 2. dated 15 August 1994 - Page 12 of 15
[14] "A Study of the Empirical Precision of Airborne Asbestos Concentration Measurements in the
Workplace by the Membrane Filter Method," Asbestos Information Association, Air Monitoring
Committee Report, Arlington, VA (June, 1983).
[15] McCrone, W., L. McCrone and J. Delly, "Polarized Light Microscopy," Ann Arbor Science (1978).
[16] Ogden, T. L. "The Reproducibility of Fiber Counts," Health and Safety Executive Research
Paper 18 (1982).
[17] Schlecht, P. C. and S. A. Schulman. "Performance of Asbestos Fiber Counting Laboratories in
the NIOSH Proficiency Analytical Testing (PAT) Program," Am. Ind. Hyg. Assoc. J., 47, 259-266
(1986).
[18] Chatfield, E. J. Measurement of Asbestos Fiber Concentrations in Workplace Atmospheres,
Royal Commission on Matters of Health and Safety Arising from the Use of Asbestos in Ontario,
Study No. 9, 180 Dundas Street West, 22nd Floor, Toronto, Ontario, CANADA M5G 1Z8.
[19] Walton, W. H. "The Nature, Hazards, and Assessment of Occupational Exposure to Airborne
Asbestos Dust: A Review," Ann. Ossup.. Hyg., 2S. 115-247 (1982).
[20] Cherrie, J., A.D. Jones, and A.M. Johnston. "The Influence of Fiber Density on the Assessment
of Fiber Concentration Using the membrane filter Method." Am. Ind. Hyg. Assoc. J., 47X8)., 465-
74 (1986).
[21] Baron, P. A. and S. Shulman. "Evaluation of the Magiscan Image Analyzer for Asbestos Fiber
Counting." Am. Ind. Hyg. Assoc. J., (in press).
[22] Taylor, D. G., P. A. Baron, S. A. Shulman and J. W. Carter. "Identification and Counting of
Asbestos Fibers," Am. Ind. Hyg. Assoc. J. 45(21, 84-88 (1984).
[23] "Potential Health Hazards of Video Display Terminals," NIOSH Research Report, June 1981.
[24] "Reference Methods for Measuring Airborne Man-Made Mineral Fibers (MMMF)," WHO/EURO
Technical Committee for Monitoring an Evaluating Airborne MMMF, World Health Organization,
Copenhagen (1985).
[25] Criteria for a Recommended Standard...Occupational Exposure to Fibrous Glass, U.S.
Department of Health, Education, and Welfare, Publ. (NIOSH) 77-152 (1977).
METHOD WRITTEN BY:
Paul A. Baron, Ph.D., NIOSH/DPSE.
APPENDIX A: CALIBRATION OF THE WALTON-BECKETT GRATICULE:
Before ordering the Walton-Beckett graticule, the following calibration must be done to obtain a counting
area (D) 100 pm in diameter at the image plane. The diameter, d (mm), of the circular counting area
and the disc diameter must be specified when ordering the graticule.
1. Insert any available graticule into the eyepiece and focus so that the graticule lines are sharp
and clear.
2. Set the appropriate interpupillary distance and, if applicable, reset the binocular head adjustment
so that the magnification remains constant.
3. Install the 40 to 45X phase objective.
4. Place a stage micrometer on the microscope object stage and focus the microscope on the
graduated lines.
5. Measure the magnified grid length of the graticule, L (pm), using the stage micrometer.
6. Remove the graticule from the microscope and measure its actual grid length, L , (mm). This can
best be accomplished by using a stage fitted with verniers.
7. Calculate the circle diameter, d (mm), for the Walton-Beckett graticule:
NIOSH Manual of Analytical Methods (NMAM), Fourth Edition, 8/15/94
NYC-WTC_000149417
OCR can misread numbers and units. Confirm readings against the page image before using them.