NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 10/AIR MONITORING - LAB
Document / 85 pages

EPA air monitoring chain of custody, Jan 2003

Machine-extracted title · confidence 95%

A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.

NYC-WTC_000149346–000149430

Folder label: “AIR MONITORING - LAB

Page image
Scanned page image, NYC-WTC_000149398
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 763, Subpt. E, App. A 40 CFR Ch. I (7-1-00 Edition) 10. Calibrate sampling pumps and their 17. A minimum of 13 samples are to be col­ flow indicators over the range of their in­ lected for each testing site consisting of the tended use with a recognized standard. As­ following: semble the sampling system with a rep­ a. A minimum of five samples per abate­ resentative filter (not the filter which will ment area. be used in sampling) before and after the b. A minimum of five samples per ambient sampling operation. area positioned at locations representative 11. Record all calibration information. of the air entering the abatement site. c. Two Held blanks are to be taken by re­ 12. Ensure that the mechanical vibrations moving the cap for not more than 30 seconds from the pump will be minimized to prevent and replacing ft at the time of sampling be­ transferral of vibration to the cassette. fore sampling is initiated at the following 13. Ensure that a continuous smooth flow places: of negative pressure is delivered by the pump 1. Near the entrance to each abatement by damping out any pump action fluctua­ area. tions if necessary. ii. At one of the ambient sites. (DO NOT 14. The final plastic barrier around the leave the Held blanks open during the sam­ abatement area remains in place for the pling period.) sampling period. d. A sealed blank is to be carried with each 15. After the area has passed a thorough sample set. This representative cassette is visual Inspection, use aggressive sampling not to be opened in the field. conditions to dislodge any remaining dust. 18. Perform a leak check of the sampling (See suggested protocol in Unit III.B.l.d.) system at each indoor and outdoor sampling 16. Select an appropriate flow rate equal to site by activating the pump with the closed or greater than 1 liter per minute (Umin) or sampling cassette in line. Any How indicates a leak which must be eliminated before initi­ less than 10 L/mln for 25 mm cassettes. Larg­ ating the sampling operation, er filters may be operated at proportionally 19. The following Table I specifles volume higher flow rates. ranges to be used:

672

NYC-WTC_000149398

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000149398Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

DEP WTC General Correspondence Form · Box DEP Box 10

NYC-WTC_000149798

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

19 shared non-person entities · Same agency, volume and box · similarity 0.961

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →