NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 08/INTERIM FINAL April 2003
Document / 161 pages

EPA interim final report on WTC background study, April 2003

Machine-extracted title · confidence 100%

Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.

NYC-WTC_000145869–000146029

Folder label: “INTERIM FINAL April 2003

Page image
Scanned page image, NYC-WTC_000145973
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

carcinogenic endpoint, a separate wipe assessment analysis should be performed taking into account childhood exposure parameters. A more complete discussion of the uncertainties associated with the methodology for surface contact assessment is presented in Appendix D.

With the exception of asbestos, the extremely limited air sampling data for specific building constituents in indoor air dictated that an assessment approach had to be based on historical data relating the concentration of fibers in air (fibers per cubic centimeters or f/cc) to the load in settled dust (fibers per square centimeters or fZcm^) [Millette and Hays 1994]. Although the empirical relationships (called K factors) are not rigorous enough to rely on for a firm health decision, they are used in this report to define what might constitute elevated building material counts that would need to be addressed on a near-term basis. This approach may overestimate potential exposures but, as such, is protective.

Developing Benchmark Levels Based on Occupational Health Standards

For fibrous glass and silica, risk-based methods were not available for indoor air due to lack of established environmental toxicity criteria. Therefore, benchmark levels were set based on occupational health standards established by the American Conference of Governmental Industrial Hygienists [ACGIH] (called “threshold limit values” or TLVs) and the Occupational Safety and Health Administration [OSHA] (called “permissible exposure limits” or PELs). TLVs/PELs are established to protect employees who might have been exposed to substances during an eight-hour day, for five days a week. For Tier I levels, TLVs/PELs were divided by ten to be more protective of residents who might be exposed to substances twenty-four hours a day, seven days a week. In addition, the TLVs/PELs were established to protect a healthy worker. For Tier HI levels, TLVs or PELs were divided by 100 to be protective of a more diverse population that includes sensitive individuals such as children, older adults, and the infirm.

The following tables show the benchmark levels developed for each contaminant of potential concern. Each table is accompanied by risk equations, toxicity criteria and a summary of any contaminant-specific assumptions that were made in developing the benchmark values.

16

NYC-WTC_000145973

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145973Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000132498 · Box DEP Box 54

A DEP report describing ambient outdoor air monitoring for asbestos in Lower Manhattan following the World Trade Center disaster.

Cited alongside this record in an Ask answer

NYC-WTC_000132628 · Box DEP Box 54

A letter from Capital Properties submitting additional air quality monitoring results for Broadway and Trinity Place buildings to the DEP.

Cited alongside this record in an Ask answer

NYC-WTC_000142802 · Box DEP Box 06

Document defining indoor air quality terms such as acid aerosols and action levels for radon remediation.

Cited alongside this record in an Ask answer

Compare copies and versions →