NYC 9/11 Public Portal Document
carcinogenic endpoint, a separate wipe assessment analysis should be performed taking into
account childhood exposure parameters. A more complete discussion of the uncertainties
associated with the methodology for surface contact assessment is presented in Appendix D.
With the exception of asbestos, the extremely limited air sampling data for specific building
constituents in indoor air dictated that an assessment approach had to be based on historical data
relating the concentration of fibers in air (fibers per cubic centimeters or fZcc) to the load in
settled dust (fibers per square centimeters or Lcm^) [Millette and Hays 1994]. Although the
empirical relationships (called K factors) are not rigorous enough to rely on for a firm health
decision, they are used in this report to define what might constitute elevated building material
counts that would need to be addressed on a near-term basis. This approach may overestimate
potential exposures but, as such, is protective.
Developing Benchmark Levels Based on Occupational Health Standards
For fibrous glass and silica, risk-based methods were not available for indoor air due to lack of
established environmental toxicity criteria. Therefore, benchmark levels were set based on
occupational health standards established by the American Conference of Governmental
Industrial Hygienists [ACGIH] (called “threshold limit values” or TLVs) and the Occupational
Safety and Health Administration [OSHA] (called “permissible exposure limits” or PELs).
TLVs/PELs are established to protect employees who might have been exposed to substances
during an eight-hour day, for five days a week. For Tier I levels, TLVs/PELs were divided by
ten to be more protective of residents who might be exposed to substances twenty-four hours a
day, seven days a week. In addition, the TLVs/PELs were established to protect a healthy
worker. For Tier III levels, TLVs or PELs were divided by 100 to be protective of a more
diverse population that includes sensitive individuals such as children, older adults, and the
infirm.
The following tables show the benchmark levels developed for each contaminant of potential
concern. Each table is accompanied by risk equations, toxicity criteria and a summary of any
contaminant-specific assumptions that were made in developing the benchmark values.