Chain of custody form for DEP environmental samples, 2001

Machine-extracted title · confidence 90%

Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.

NYC-WTC_000145695–000145868

Folder label: “NO INFO

Page image
Scanned page image, NYC-WTC_000145815
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document Tabte 16.0 The Use of an Air Filtraton Device Reduces the Occurrence of Overloaded Air Sample Filters AFD Used Y6S Number of Unis with or without Mfex for the trat clemnime 16 Number of Unts with One or More Overtoads Percentage of Units with Overlonds 38.9% 57.1% AFD Used Yes NO Number of Units with or withond AFDs for the Second Cleaning Number of Units with ar Least One Overload Percentage of Units with Overloads 0.05 40.0% Ais Used Number of Urts with or without AFD: for the Third Cleaning Number of wats w/at Least One Overload 0 Yes No Percentage of Units wth Overioaas 0.0% N/A 5.10 HVAC System The HVAC system was cleaned in two of the commercial units. The system was cleaned by professionals using equipment and techniques common to the industry that included HEPA- filtered vacuums, air whips, air washing and soap and water washes. Wipe samples were collected prior to cleaning and after cleaning for comparison. The results indicate that overall there was a reduction of an order of magnitude for the compounds which were detected. In The Food Exchange, lead was reduced from 1,310 ug/m' to 159 ug/m' (average), MMVF was reduced from 11,732 S/cm' to<57.3 S/cm? -. In the Lemongrass Grill, there was a reduction in lead concentrations from 10,700 ug/m° to 95.95 ug/m (average). This indicates that standard HVAC cleaning methods and equipment reduced the concentrations of WTC-related contaminants by an order of magnitude. The study found that standard HVAC cleaning methods educed the concentrations of WTC-related contaminants, 117 NYC-WTC_000145815

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000145815Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000136990

Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.

Cited alongside this record in an Ask answer

NYC-WTC_000153313 · Box DEP Box 26

Updated memorandum defining the Red Zone boundaries and listing authorized agencies for entry into the restricted area.

Cited alongside this record in an Ask answer

NYC-WTC_000149744 · Box DEP Box 10

Policy document outlining NYPD access requirements for building owners and contractors at the site in October 2001.

Cited alongside this record in an Ask answer

Compare copies and versions →