NYC 9/11 Public Portal Document
5.5 Cleaning Effectiveness
Cleaning effectiveness was determined using two endpoints. One endpoint was the reduction in
contaminant concentration between the pre-cleaning and post-cleaning event concentrations in
each unit. The other endpoint was the ability to meet health-based benchmarks. The evaluation
of both endpoints proved that cleaning indoor environments using standard cleaning techniques
(vacuuming and wet wiping techniques) succeeded in reducing contaminant concentrations below
health-based benchmarks. This is evidenced by the fact that all residential units, commercial units,
and common areas had marked reductions in contaminant concentrations between cleaning events.
In addition, all of the residential units, commercial units, and common areas exhibited
concentrations that were below health-based benchmarks at the conclusion of the study.
The comparison of pre-cleaning and post-first cleaning concentrations for asbestos wipe and air
samples, lead wipe and micro vacuum samples, MMVF wipe samples, and asbestos air samples
fi-om post-second and third cleaning events is presented in Table 11.1. This table shows the
average concentration of the pre-cleaning samples in comparison with post-cleaning events, with
the difference presented in the last column on the right. Exceedances of COPC by cleaning event
are presented in Table 11.2. Note: Due to the quantity of information presented, Table 11.1 and
Table 11.2 are presented at the conclusion of this discussion.
The aggregate removal efficiencies for the nine apartments that were identified as being the most
heavily contaminated, based on pre-cleaning results, are presented in Figure 1.0, This figure
shows that with the exception of two apartments, there was a net decrease for each contaminant
regardless of sampling media or test methods. Asbestos wipe samples for one apartment and
MMVF wipe samples for another apartment were the two exceptions. The reason for this is
unknown.
As indicated in Section 2.4, a total of eleven cleaning methods were tested in the study. These
eleven methods were distributed among 25 spaces, although one of the methods, 4A, was used in
all of the common spaces and commercial spaces. Because the different test methods that were
evaluated were similar in nature, and the number of apartments that were available for testing the
methods was limited, all of the test methods were identified as being able to reduce contaminant
concentrations and no specific test method was identified as being more effective. Therefore, the
central theme of these methods, specifically vacuuming and using wet wiping techniques, was
demonstrated to be effective for reducing contaminant concentrations.
109
NYC-WTC_000145807
OCR can misread numbers and units. Confirm readings against the page image before using them.