NYC 9/11 Public Portal Document
Table K-4: Indoor Air Test Results from October 23,2001
PCM Analysis TEM Analysis
Sample
Sample Volume 8».5.5 S>5
Adcfress _nL_ &CC 8Zmm2 limiY [4]
100 Church St (front of 1927/8)
100 Church St (Lobby) JIS 2400 0.002
2400 0.002
na
na
<20
<20 2 2
100 Church St (1909/1910)
100 Church St (1902/1903)
100 Church St (Alley 1960)
11933
11934
11935
2160
2400
2400
0.003
0.001
<0.001
’ts<7
na
na
na
<20
<20
<20
0
0
0
2
0
100 Church St (Alley 1941) 11936 2400 <0.001 <7 na <20 0 0
100 Church St (1935/1937) 11937 2400 0.004 21.66 na <20 0 0
100 Church St (1835/1837) 11938 2400 <0.001 <7 na <20 0 0
100 Church St (18FL-SW comer) 11939 2400 <0.001 <7 na <20 0 0
100 Church St (IS"* main lobby) 11940 2400 0.005 30.57 na <20 0 0
KEY:
np = sample volume not provided on data sheets.
na= not analyzed for this metric.
NOTES:
[1] = sample volume for TEM (AHERA method) is 1200 liters for 25 mm filter
[2] = fibers per millimeter squared
[3] = structures equal to or greater than 0.5 micrometers and less than or equal to 5 micrometers in length
[4] = structures greater than 5 micrometers in length
General Services Administration Monitoring of Federal Buildings
From September 13,2001, through January 2, 2002, the General Services Administration, which
is responsible for Federal building management, arranged for indoor environmental testing at
Federal buildings located at 290 Broadway, 26 Federal Plaza, 201 Varick Street, and 1 Bowling
Green. Over 100 air samples were analyzed and all samples were below the AHERA standard of
70 s/mm2. All but four air samples analyzed by TEM were non-detect for asbestos. The four
samples that detected asbestos all occurred between September 13 and September 19,2001. Two
samples showed 25 s/mm2 and two samples could not be analyzed because the filters were
overloaded. The only testing for asbestos in dust was conducted on September 14, 2001. Three
dust samples collected in the lobby of 290 Broadway and two collected outside the building on
September 13, 2001, showed the presence of chrysotile asbestos by TEM analysis. The results
for these tests only reported whether asbestos was present or not, not the percentage of asbestos
in the sample. Table K-5 through K-7 provide more information on the results of indoor testing
of Federal buildings.