NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
NYC-WTC_000145027–000145344Folder label: “NO INFO”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
APPENDIX A DEFINITIONS
1. Access Doors: Covers for service openings consisting of pre-fabricated operable or removable entry panels, which are installed in a ventilation system to facilitate inspection and maintenance services.
2. Air Conveyance System, Air Handling System, HVAC System, Ventilation System: The ventilation system is any interior surface of a building's air distribution system for conditioned spaces and/or occupied zones (See definition of air handling system, ASHRAE 62-1989). This includes the entire air distribution system from the points that the air enters the system to the points that air is discharged from the system. The return air grilles, air ducts (except ceiling plenums) to the air handling unit (AHU), the interior surface of the AHU, mixing box, coil compartment, condensate drain pans, humidifiers, and dehumidifiers, supply air ducts, fans, fan housing, fan blades, spray eliminators, turning vanes, filters, filter housings, reheat coils, and supply diffusers are all considered part of the ventilation system.
3. Air Filtration Device (also referred to as Negative Air Machine): An external air moving device which can be temporarily connected to a section or sections of an ventilation system to create negative airflow for cleaning and remediation procedures, employing a minimum of DOP- tested HEPA final filtration if exhausted indoors.
4. Air Washing; For duct cleaning, this term applies to the use of pressurized air, in combination with a Vaccuum Collection Device, for transporting dislodged debris into the vacuum collection equipment.
5. Ceiling Plenum: A non-ducted area between the ceiling over a conditioned building space and the floor above, through which air is transported to a conditioned space fi-om an ventilation system (ceiling supply air plenum), or from a conditioned space to an ventilation system (ceiling return air plenum).
6. Coils: Devices inside the ventilation system, which temper and/or dehumidify the air transported by the ventilation system. These include heat exchangers, with or without extended surfaces, through which either water, ethylene glycol solution, brine, volatile refrigerant, steam, or electricity is circulated for the purpose of total cooling (sensible cooling plus latent cooling) or sensible heating of a forced-circulation air stream (See ASHRAE 33-78 and ARI 410-91).
7. Debris: Any solid materials, including particulate substances, in the ventilation system not intended to be present.
8. DOP Testing: The percentage of removal of 0.3 micrometer particles of dioctylphthalate (DOP) is used to rate high efficiency air filters, those with efficiencies above about 98 percent (See Military Standard 282, U.S. Department of Defense, 1956).
9. Ductwork (Ducts): A system of passageways for distribution and extraction of air (See ASHRAE Terminology ofHeating, Ventilation, Air Conditioning, and Refrigeration, 1991).
1
NYC-WTC_000145222
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000149537
Instructions and sections for collecting sample location data from a specific building interior.
22 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
20 shared non-person entities · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
13 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
11 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
20 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139712
Series of emails forwarding a draft memo between DEP staff members for review and finalization.
17 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155394
Transmission of cleanup and environmental monitoring documentation for 114 Liberty post-WTC dust remediation project.
12 shared non-person entities · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164784
Transmission of revised asbestos sampling results for residential samples collected November-December 2001.
15 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000125845
Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.
25 shared non-person entities · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000150209
Laboratory report listing PCM and TEM asbestos air sampling results collected on September 26, 2001.
Cited alongside this record in an Ask answer
NYC-WTC_000134871
EPA Region 2 letter regarding revised environmental work plan submission for two buildings including asbestos, health, and safety assessment components.
Cited alongside this record in an Ask answer
NYC-WTC_000094912
Invoice detailing billing for bulk and air sample analysis results including PLM, PCM, and TEM testing at 44 Wall Street.
Cited alongside this record in an Ask answer
NYC-WTC_000096623
Part II of a health and safety plan for remediation and deconstruction at 30 Warren Street in January 2006.
Cited alongside this record in an Ask answer
Archival folder label for September 11 news clippings from the Office of the Mayor, identified as Folder 0123.
Cited alongside this record in an Ask answer