WTC Residential Testing Results
The work of cleaning and testing residences in lower Manhattan (south of Canal
Street) is underway. Depending upon the assistance requested, EPA is arranging for
licensed contractors to clean and/or test residential units (fact sheet) for asbestos in
air. There is no charge for this service. Requests for assistance will be accepted until
teifiSW December 28, 2002 via the Web or by calling EPA's toll-free World Trade Center
hotline (1-877-796-5471).
Asbestos in air test results for individual residences are provided only to residents of
the affected unit. Aggregate test results are provided here. The locations of
residences that have cleared or not cleared EPA's testing criteria will be identified by
block.
1
s EPA is committed to setting the most stringent standards that can be technically
achieved when testing residences for asbestos in air. We have set an initial
risk-based clearance level for asbestos of 0.0009 fibers per cubic centimeter (f/cc).
This means that if 10,000 people are exposed to this level of asbestos for 30 years,
iiil there may be one more case of cancer than if the group had not been exposed at all.
Testing for asbestos (fact sheet) in air calls for moving a measured volume of air
3 filter, then examining that filter under a microscope equipped with a grid and
counting the number of asbestos fibers found. Problems arise when too many dust
and fiber particles are captured by the filter. The filter becomes overloaded and
technicians examining it under the microscope cannot separate out or identify
individual fibers. Residences where this occurs are listed as ”Not Determined." In a
residence where only testing was conducted, EPA recommends that the home be
cleaned and re-tested. In a residence where both cleaning and testing were done,
EPA will attempt to identify potential sources and will then re-clean and re-test the
home.
Test results below reflect analytical results received through November 6th.
During the initial stage of cleaning and testing, results will be updated on a weekly
basis. Once data flow is established, this table will update automatically as test reults
are entered.
Test Only
Quadrant (Mag) Total Requests Cleared Not Cleared Not Determined
A li:
B ...... o; _____ .„3.
C 256 36 ....... 3^ 2
D 0 t
7
■
Total 1176 156 4
Clean and Test
1 of? 11/14/02 11:41 A