NYC-WTC_000140796
Minutes from the EPA Indoor Air Working Group meeting held on May 9, 2002, at 290 Broadway.
9 shared non-person entities · Same agency, volume and box · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗Attendance list and discussion notes from the May 23, 2002 meeting at EPA Region 2 offices regarding contaminants.
NYC-WTC_000140731–000140734Folder label: “M.G: EPA INDOOR AIR WORKING GROUP MTGS.”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
*>
r
- For the COPC justification, it is impossible to pull in all of the available data that is out currently but the report will be as comprehensive as possible. The use of XRD analysis was discussed with other federal agencies and they were comfortable with the lab procedure. The clearance levels for asbestos will be based on the Asbestos Hazard and Emergency Response Act (AHERA) standards. - NYC is using the 0.01 fibers per cubic centimeter PCM clearance level, therefore, the relationship to the AHERA standard should be explained. - EPA will take the lead in developing a policy to address questions on the correlation of AHERA to other standards. There is concern about the consistency of the acceptable risk range. - We are using 10^, however, 10 ® is preferred and considered more protective. - 1 O’® is probably below background levels but we do not have that data yet. - The Working Group decided that 10 ® is not practical and will include an explanation in the COPC report. The peer reviewers recommended that a standardized approach should be used for the factors. Where this is not achievable, it will be explained in the COPC report. Mold will be explained as not being a COPC in the report.
2. Peer Review • EPA’s Regional Administrator recommends that a formal peer review process should take place. However, the Background Study and Pilot Cleaning activities should not be held up. • It is anticipated that the time needed for each project will eventually cause the projects to get into the proper alignment. If any anomalies are encountered, they will be dealt with as they occur. • The members of the Working Group will take this recommendation back to their management and will report on their support or opposition to the Working Group.
3. Pilot Cleaning • The draft SOW for the Pilot Cleaning will be shared with the Working Group, preferably before the next meeting.
4. FEMA Submission • Dore Laposta shared a draft of the scope of the EPA/NYC indoor air program that was submitted to FEMA and is being shared with all of the principals. • FEMA signed off on this version. • EPA’s Regional Counsel and the legal subgroup are currently reviewing the scope.
5. NYC and Exterior Cleaning Updates • There may only be one building whose interior has never been cleaned. • Two bids for the Indoor Air Hotline have been received and they will be opened at noon.
NYC-WTC_000140732
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000140796
Minutes from the EPA Indoor Air Working Group meeting held on May 9, 2002, at 290 Broadway.
9 shared non-person entities · Same agency, volume and box · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140735
Attendee list for the EPA Indoor Air Working Group meeting held at 290 Broadway on April 4, 2002.
9 shared non-person entities · Same agency, volume and box · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140684
Attendance list for the April 18, 2002 EPA indoor air working group meeting at 290 Broadway.
9 shared non-person entities · Same agency, volume and box · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · Same agency, volume and box · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160273
EPA-distributed memo to federal, state and city agencies with World Trade Center environmental response status updates.
10 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000160208
Correspondence between EPA and city agencies discussing ongoing Lower Manhattan environmental efforts.
9 shared non-person entities · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000147982
A project proposal outlining the timeline, methods, and justification for cleaning HVAC systems in residential units affected by World Trade Center dust.
10 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149798
Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.
6 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000144741
Standard administrative notice requiring the retention of original World Trade Center records as evidence for future legal actions.
8 shared non-person entities · 1 shared topics · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗4 shared non-person entities · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000160273
EPA-distributed memo to federal, state and city agencies with World Trade Center environmental response status updates.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151555
EPA Region 2 responds to a congressional inquiry about the joint EPA-DEP program for testing and cleaning lower Manhattan homes after the WTC collapse.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151567
EPA Region 2 response to inquiry about the joint EPA-DEP World Trade Center residential dust cleanup and testing program funded by FEMA, noting approximately 5,300 requests…
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151544
Letter responding to inquiries about the joint EPA and DEP program designed to protect residents from residual dust at the World Trade Center site.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140640
Notice instructing staff to preserve original World Trade Center documents as potential evidence in future legal actions against the City.
Filed in the same folder
NYC-WTC_000140641
Agenda for a meeting discussing status of activities, public requests, and development of sampling and cleaning plans for WTC debris.
Filed in the same folder
NYC-WTC_000140642
Introduction to a cross-agency group tasked with identifying contaminants of concern and establishing health-based screening levels for the indoor environment.
Filed in the same folder
NYC-WTC_000140643
Documentation describing the methodology for identifying contaminants of concern using historical data and qualitative toxicity screens.
Filed in the same folder
NYC-WTC_000140644
Summary of contaminants removed from the review list due to being non-detectable or found only in trace amounts, including all VOCs.
Filed in the same folder