AIRBORNE ASBESTOS, BUILDING INTERIORS PCM-equivalent
MANHATTAN fibers permilliiter (f/mL)
PCM-equivalent fibers and bundles longer than 5 Micrometers
Ground Zero Task Force Study,*® data from Table 16. HIGH EXPOSURE BUILDING, 250 South End
Ave, BEFORE CLEANUP, PASSIVE CONDITIONS (no activities to disturb dusts). Fibers and bundles
longer than 5 micrometers. TEM analysis using the International Standards Organization ISO10312
direct transfer method
250SEA-10D-A1. Apartment 10D, den 0.063
250SEA-10D-A2, Apartment 10D, den 0.060
250SEA-10D-A3, Apartment 10D, living room 0.048
250SEA-10D-A4, Apartment 10D, living room 0.075
250SEA-10D-A5, Apartment 10D, bedroom 0.081
Ground Zero Task Force Study, Table 8.*® PCM-equivalent fibers and bundles longer than 5
micrometers. PASSIVE CONDITIONS (no activities to disturb dusts) LOW EXPOSURE BUILDING, 45
Warren St. BEFORE CLEANUP. TEM analysis using the ISO10312 direct transfer method.
45 WAR-2-A1,2nd floor living room “not statistically significant"
[detected but uncertain]
45 WAR-2-A2, 2nd floor living room ND
45 WAR-2-A3, 2nd floor master bedroom 0.010
HP Environmental Study, Table 6.*^ Two building interiors near Ground Zero. PASSIVE
CONDITIONS, BEFORE CLEANUP. Analyses by the modified EPA Level II TEM method where
samples were heavily loaded (all 3 samples below where asbestos detected), which uses indirect
preparation to separate out interferences from other non-asbestos parts of WTC dusts. Study
demonstrated that up to 10 times more asbestos was detectable by this method.
Sample 2 0.007
Sample 7 0.167
Sample 9 0.346
8 out of 11 samples, interior of 2 buildings near collapsed WTC towers, ND
EPA data, PASSIVE CONDITIONS, AFTER INCOMPLETE CLEANUP. EPA has been usually not
using the simple AHERA TEM clearance test method inside buildings at the request of detected
tenants and others. This isaviolation of the AHERA protocols, which only allow this
test to be performed AFTER professional and complete asbestos abatement, which
must thoroughly clean all surfaces. The AHERA TEM clearance method is only meant
as an inexpensive, but not an assurance by itself, that asbestos has been adequately
abated. The use of a leaf blower or other strong fan in conjunction with taking the air
sample would be needed for that in addition to wipe samples of surfaces. EPA Region
8 found that at Libby, even when there were activities going on to disturb dusts, air
monitors worn by people sitting on couches, etc. always gave higher readings than a
stationary air monitor in the same room (such as is the case in the AHERA TEM test).