NYC 9/11 Public Portal Document
TABLES - LOWER MANHATTAN ASBESTOS DATA
Note: The total asbestos levels found in Manhattan by the Ground Zero Task Force study are
much higher. The reason why only the “PCM-equivalent” asbestos levels are given in the tables
below is to make comparison with the Libby data possible. See the explanation at the beginning
of this memo.
SETTLED ASBESTOS DUSTS, BUILDING INTERIORS PCM-equiva lent
MANHATTAN structures per square
Fibers and Bundles (Structures) Longer than 5 Micrometers centimeter (s/cm^)
Ground Zero Task Force Study,®® data from Table 21. HIGH EXPOSURE BUILDING, BEFORE
CLEANUP, 250 South End Ave. Fibers and bundles longer than 5 micrometers. Heavy visible dust
layer, could still read addresses on envelopes on table and see the lines on a yellow legal pad on the
table. Windows had been blown outfrom some apartments. [Note Table 21 says fibers/cm^ , but title
of table is “fibers plus bundles”, which equals structures.] TEM analysis using American Society for
Testing and Materials ASTM D6480-99.
250SEA-10D-D1 (A) (sample collected with toothbrush sample) top of cupboard with 21,000
glass doors
250SEA-10D-D1 (B) (wipe sample) top of cupboard with glass doors 19,000
250SEA-10D-D2 (A) (sample collected with toothbrush) living room high boy side table 18,000
250SEA-10D-D2 (B) (sample collected with toothbrush) living room high boy side table 28,000
Ground Zero Task Force Study,” data from Table 19. LOW EXPOSURE BUILDING. BEFORE
CLEANUP, 45 Warren St., dust layer visible on dark table, grain of wood stiH visble. 5 blocks from
Ground Zero, building faced north away from Ground Zero. Only light dusting. See photo in study
itself. Fibers and bundles longer than 5 micrometers. [Note Table 19 says fibers/cm^ , but title of table
is “fibers plus bundles", which equals structures] TEM analysis using American Society for Testing and
Materials ASTM D6480-99.
45WAR-2-D1, 2nd floor, living room table near window, wipe sample 2,300
45WAR-2-D2. 2nd floor, living room window sill, wipe sample 60,000
45-WAR-5-D1, 5th floor, living room, window sill, wipe sample 79,000
45-WAR-5-D2, Sth floor, roof level office, green wooden chair, wipe sample 22,000
NY Environmental Law and Justice Project. 105 DUANE ST, AFTER CLEANUP.** Microvacuum
method followed by American Society for Testing and Materials ASTM D-5755.
Sample inside central air conditioning duct. Total asbestos concentration reported as 111,000
555, 000 s/cm®. Estimated that 20% of the structures are over 5 micrometers, or
111,000 s/cm®
-16-
NYC-WTC_000140250
OCR can misread numbers and units. Confirm readings against the page image before using them.