a. Based on consultation with resident or owner, aggressive or modified aggressive air
sampling will be conducted. Residents shall not be present in their apartment during
aggressive air sampling activities.
We do not see the benefit or need to -U_s_c a leaf blower to_ aggitate the ind-oor enyironroent to this extent
during sampling. An electric leafblower is capable ofproducting air velocities of 155 to 210 mph according
to Scars. These air velocities are far removed from any air velocities that occurinindoor environments.
(And, yes, you can reduce the air velocities from a leafblower to some extend, but what is thepoint?') We
understand tihatsuchatec^quewaS-Used in mmCTs’eabins in Montana but this isless than pursuasive given
the differences between those indoor environments and those ofoccupied apartments in Manhatten, Why
would we dp_this?_ What is the benefit? We are not aware ofany expert on indoor air quality who has used
or would advocate die use_ ofsuch high air velocities. In addition, the fact that we propose that the resident
or owner decide whether to use iive (leafhlower)pr tnodified aggressive sampling protocols sjiggeste
that the aggressive protQcpl is not goro or key to our study. Moreover, it will add another stratification to
our study and reduce our power to- interpret the study results. There is also the potential to damage
furnishings in the dwellings throng theuse ofthis technique. It will only take a fey highly publicized incidence
to tarnish our whol effort. We recommend that we do not propose the use offiip aggressive sampling
protocoj,
1. Before beginning-aggressi veair SdUlpmu;g, forced air equipment (such as a 1
horsepowerelectric leafblower) shalFbe used todircctexhaust air against walls,
ceilings, floors and other surfaces. \^Qicn directing flic exhaust, caution shall be
taken to mimimzc disturbance and potential damage to hxrnislnngs and pc];rsonal
beiongaigs:
hr For modified aggressive air sampling forced an equipment shall not be employed.
The terminology used here is incorrect and confusing because a 20-in fan is a form
of forced air equipment.
iii. All other procedures arc identical for aggiessivc and modified aggiessive air
sampiittg:
b. One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low
speed. The fen shall operate continuously throughout sampling and shall not be turned off
until sampling is completed. How long before sampling should the fan be turned on? This.
is an unportant issue because we want to sample at or near_^eady state and the air moved
by the fan has a time constant the will partially determine how long it wll take to achieve
steady state. At a minimum.-the time prior tQ_ sampling when the fanjshould be turn on
should be specified..
c. For studio apartments 3 air samples shall be collected. For 1 -bedroom apartments and
above 5 air samples shall be collected. Sampling equipment shall be placed in living areas
and away from obstructions. The sampling cassette must be placed on a tripod directed
downward at .a 45. degree angle and not taped to existing surfaces.
d. Common spaces will be sampled without flic use offorced air devices (fens, leafblowcrs
etc): For small spaces, less than 160 square feet, 3 air samples will be collected. For large