Determination of .0009f/cc as clearance value for asbestos air monitoring
Risk Assessment
The IRIS inhalation unit risk for asbestos is 2.3 E-01 per fZcc. Here's how this unit risk is interpreted.
Exposure over a lifetime (i.e., 70 yrs) to 1 f/cc of asbestos results in a cancer risk of 2.3 E-1. To get the
fiber concentration equating to a 1 E-04 (one-in ten thousand risk - for lifetime exposure) the
following equation is used:
23= .0001
1 f/cc X
x = ,0001
.23
X = .0004 f/ec this is the fiber concentration that equates to a 1 E-04 risk for 70 year exposure.
To adjust the exposure duration to 30 years, multiply .0004 ficc by 70 = .0009 ficc
30
Analytical Methods
PCM NIOSH 7400 followed by AHERA TEM analysis should be used on all samples. AHERA TEM
measures all fibers > .5 um. Additionally, the lab should record all fibers that are > 5 um to determine
the PCMe value.
PCMe is determined by counting all fibers > 5 um with a 3:1 aspect ratio by TEM analysis. In our
PCMe calculations we are using a conservative approach of counting all fibers >5um.
Therefore, the analytical result of fibers >5 um will be compared to .0009 ficc to measure success in
achieving the clearance value.
Sampling Approach
Air sampling pumps with a maximum flow rate of 15 liters per minute should be used along with sample
cassettes with mixed cellulose ester filters having a pore size of .8 um. The minimum sampling volume
required is 3600 liters to achieve the clearance criteria.