Timeline for receiving analytical results
Asbestos - 3 days from receipt of samples
Metals - 5 days from receipt of samples
Calculation of .OOOgf/cc as 30 year risk value:
The IRIS inhalation unit risk for asbestos is 2.3 E-01 per f/cc. Here's how this unit risk is interpreted.
Exposure over a lifetime (i.e., 70 yrs) to 1 f/cc of asbestos results in a cancer risk of 2.3 E-1. (This is an
upper bound estimate- and it is based on a substantial data base of occupational cohorts.) To get the fiber
concentration equating to a 1 E-04 (one-in ten thousand risk - for lifetime exposure) set up the following
equation:
BWil1
1 f/cc X
X = 1
.23
X S5H4 f/cc This is the fiber concentration that equates to 1 E-04
risk for 70 yr exposure.
To adjust the exposure duration to 30 yrs, multiply SEE4 f/cc by 70 SEE 9f/cc
30
Explanation of how the lab will achieve .OOOQf/cc:
The ultimate sensitivity of the asbestos TEM analysis is based upon two factors: (1) the volume of air
sampled, and (2) the area of the sample filter that is looked at with the TEM - this is referred to as number
of grid openings that are scanned under the electron microscope.
in theory, the sensitivity for the TEM is extremely low, but in reality the "practical" sensitivity depends upon
how much air can be drawn through a filter before the filter gets "clogged" with non asbestos particulates,
and how much you willing to pay the lab to analyze a large number of grid openings (for AHERA, 10 grid
openings are usually scanned).
For our needs in the WTC, we desire to reach a sensitivity of SEE9. If we were to collect 1200 liters of air
(recommended by AHERA), the lab would have to scan 30 grid openings to reach the 0;SEE9. This
constitutes about 3 times more laboratory effort to reach our sensitivity needs than would be needed for
typical AHERA. To keep the laboratory effort at a minimum, we have recommended that 4000 liters of air
be sampled. At this volume, the lab only has to read 9 grid openings to get to 0. SEB 9.
There is the possibility that we will not be able to sample 4000 liters of air in the indoor studies. Efforts at
Libby have shown that the typical filter used for asbestos analysis (0.45 micron) became easily clogged in
homes where the residents were smokers. In these cases, they switched over to 0.8 micron filters, and in
many instances, these also became clogged. In those cases where we will not be able to sample 4000
liters, then we will either have to have the lab scan more grid openings or report a higher sensitivity. For
example if we can only collect 2SEE liters, the lab will have to scan 18 grid openings to reach the 0;SEE9.
FYI: The calculation for sensitivity is