NYC 9/11 Public Portal Document
07/21/2003 14:57 FAX I 002
Confirmation Number 002020852863 Assigned PM:
SIN: 1065475 Scheduled Date:
HE'D Sequence Number 27138 Scheduled Time:
Contact Information:
Requestor Name: Paul M Ttumbore
Address: 200 Rector Place
Floor/Apartment: 29th - Apt 29H
Phone Number: 212 652-0429 / 212 786-0340
Cleaning Contractor Information:
Cleaning Firm: 1142 AWPJ Scope: or B
License Number:
Phone Number;
Project Monitor: QJ&k24AA
Ucense Number:
Phone Number: 8
OW8KIF WA PM
Cleanup (Scope A or B) a]ol4B IMIlAl s
Wet methods discussed with owner/tenant
(some$, window sill, wells, and guards cleaned
Interior windows, screens, and wells cleaned E1 n - z
-
Ceiling HEPA vacuumed
Vertical walls HEPA vacuumed
All horizontal surfaces HEPA vacuumed
Floors HEPA vacuumed (if determined not to cause damage)
.t iit li; itbrizontal surfaces wet wiped
Curtains, drapes, btics (materiaIs that-cannot be►wetwiped) HEPA vacuumed twice
C>arpets/fk,amiture cleaned with hot water extraction units
If surfaces not wet methods, than vacuumed a second time
Paperworklboolo HEPA vacuumed
Electrical outlets HEPA vacuumed
Window AC units cleaned
Intake/discharge registers for common HVAC systems cleaned
Appliances cleaned and moved to clean the footprint (HEPA or wet mopping)
Refrigerator cooling tubes bntshed and HEPA vacuumed
1st foot of exhaust duct work (stoveldryerlbathroom vents) cleaned
Exhaust fans HEPA vacuumed/wet wiped
Solid objects (electrical equipment, exercise equipment) HEPA vacuumed/wet wiped
Dishwasher toe plates removed and the floor beneath cleaned
Baseboard heaters cleaned
HEPA- AFC)s run continuously during cleaning operation
Visual Inspection of cleanup conducted
Unobstructed closet floors cleaned
Visual Inspection Passed, Authorize Air sampling
PM slgr>abuo:
DBtamme:
NYC-WTC 000136040