NYC 9/11 Public Portal Document
DEC -06-2001 04:08 PM ACT INC. 732 321 3666 P.02
■ Accredited Environmental Technologies, Inc.
■ December 7, 2001
■ Ms. Carolyn Baiiley
CCMH Fin Center LLC
■ c o Claris Services Corporation
■ 6903 Rockledge Drive, Suite 920
Bethesda, MA 20817
■ RE: New York Financial Center Marriott, 85 West Street, New York, New York
■
Dear Ms. Bailey:
■ Attached are the laboratory results for airborne asbestos samples collected at the above referenced
location. These samples were collected and analyzed by Accredited Environmental Technologies,
■ Inc. far comparison with the clearance standards for airborne asbestos established by the New
York City Department of Environmental Protection Asbestos Control Program (Title 15,
■ Chapter 1). Sample collection occurred under normal occupancy conditions on December 3,
2001. All samples were collected with high volume sampling pumps with sample durations of
■ approximately five hours and are considered representative of background fiber concentrations
■ throughout the first three floors of the building.
■ Results indicate that fiber concentrations in the background samples were all below 0.01 F/cc, a
level considered acceptable for occupancy according to the Department of Environmental
■ Protection standards.
■ Samples were analyzed by Phase Contrast Microscopy per NIOSH Method 7400 for asbestos
fibers. This method measures total airborne fibers and does not distinguish fiber morphology. All
■ structures with a length to diameter ratio of 3 to I or greater and a length greater than 5 microns,
■ are considered to be fibers and are counted as such
■ If you have any questions or require additional information, please do not hesitate to contact our
office.
■
S. ly,
■
■ tic H+ousekneclrt~
■ Vice President
EH/bg
■
■
■ 335 High Street • Metuchen, NJ 08840 • (732) 321-0666 • FAX: (732) 321.3666
■
NYC-WTC 000131235
OCR can misread numbers and units. Confirm readings against the page image before using them.