NYC 9/11 Public Portal Document
OCT-22-2001 03:57 PM AET INC. 732 321 3666 P.02
a
■
■
Accredited Environmental Technologies, Inc.
• October 22,2001
• Ms. Carolyn Bailey
CCMH Fin Center LLC
e% Claris Services Corporation
• 6903 Rockledge Drive, Suite 920
Bethesda, MA 20817
RE:New York Financial Center Marriott,85 West Street, New York,New York
■ Dear 1Vta. Bailey:
Attached are the laboratory results for airborne asbestos samples collected at the above referenced
•
location. These samples were collected and analyzed by Accredited Environmental Technologies,
• Inc. for comparison with the clearance standards for airborne asbestos established by the New
York City Department of Environmental Protection Asbestos Control Program (Title 15,
Chapter 1). Sample collection occurred under normal occupancy conditions on October 18 and
■ October 19, 2001. All samples were collected with high volume sampling pumps with sample
durations of approximately four to six hours and are considered representative of background
fiber concentrations throughout the first five floors of the building.
Results indicate that fiber concentrations in the background samples were all below 0.01 F/cc, a
level considered acceptable for occupancy according to the Department of Environmental
Protection standards.
• Samples were analyzed by Phase Contrast Microscopy per NIOSH Method 7400 for asbestos
. fibers. This method measures total airborne fibers and does not distinguish fiber morphology. All
structures with a length to diameter ratio of 3 to I or greater and a length greater than 5 microns,
are considered to be fibers and are counted as such.
If you have any questions or require additional information, please do not hesitate to contact our
office.
■ Sincerely,
Eric Houseknecht
Vice President
EH/bg
a
a
335 High Street • Metuchen, NJ 08840 • (732) 321-0666 • FAX: (732) 321-3666
n
NYC-WTC 000131262
OCR can misread numbers and units. Confirm readings against the page image before using them.