Results ranged from less than 0.003 to 0.008 total fibers per cubic centimeter of air (f/cc).
These results are below the New York State Department of Labor and New York City
Department of Environmental Protection action and clearance level of 0.01 f/cc.
It is important to note that the sample analysis method used quantifies all fibers visible under
the microscope and does not distinguish asbestos from non-asbestos fiber types. Therefore,
actual asbestos fiber concentrations could have been lower than reported. Although not
included in our contract workscope for this project, representative samples were analyzed by
transmission electron microscopy and no asbestos fibers were identified.
Laboratory reports in support of this project are attached. Please contact me if you have any
questions.
Sincerely,
Colden Corporation
Christopher J. Wesle IH
Project Manager
NYC-WTC 000131055